Where a guy support is used within either the width of a circulation path or 24 inches maximum outside of a circulation path, a vertical guy brace, sidewalk guy or similar device shall be...
Search Results "Vertical Alignment"
Commonly Searched Documents
-
11B-307.4.1 Guy braces
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
Single-User Toilet Rooms: Split Plumbing
., one of the segments aligned with the route into the room)....
-
A. Arena Assembly Seating:
Each Companion Seat shall be located to provide shoulder alignment with the adjacent Wheelchair Seat as shown on Exhibit 1. ...
-
11B-502.6.4.2
Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower side aligned...
-
11B-502.6.4.2
Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower side aligned...
-
Beveled: ADA Standard Section 303.3
Section 303.3 covers the current ADA Standards for beveled level changes.
-
General: ADA Standard Section 306.1
Section 306.1 of the ADA Standards covers information in the current ADA Standards for knee and toe clearance.
-
Visible Signals: ADA Standard Section 407.2.2.2
Section 407.2.2.2 covers the current ADA Standards for elevator visible signals.
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head and foot end of the bed....
-
1131A.1 Changes in level not exceeding ½ inch
When changes in level do occur, they shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide....
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide. ...
-
11B-411.2.1.3.4 Position
The face of individual elements or group of individual elements that are operated by user input shall slope away from the user at 15 to 25 degrees from the vertical plane. ...
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
Spaces and Elements: ADA Standard Section 206.2.4
Section 206.2.4 covers the scoping requirements in the most current ADA Standards for accessible routes connecting spaces and elements within a building.
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location....
-
11B-306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
Wheelchair Spaces
Wheelchair spaces should not overlap required exit widths or circulation paths and should provide for shoulder-to-shoulder alignment with occupants of adjacent seats (an important consideration...