Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
Search Results "Seat Designation"
Commonly Searched Documents
-
11B-1008.4.4 Entry points and seats
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
§ 38.27(b)
(b) Each securement location shall have a sign designating it as such....
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat....
-
Implementation Challenges for Interiors (slides 16 and 17)
Prescriptive requirements are great, [if they are] backed by research, but that also may limit the design creativity and options and force someone to design something somewhere that may...
-
11B-221.2.2 Integration
The requirement that wheelchair spaces be an "integral part of the seating plan" means that wheelchair spaces must be placed within the footprint of the seating area....
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
4.32.2 Seating
If seating spaces for people in wheelchairs are provided at fixed tables or counters, clear floor space complying with 4.2.4 shall be provided....
-
M303 Diagnostic Equipment Used by Patients Seated in Wheelchair
M303 provides technical criteria for diagnostic equipment used by patients seated in a wheelchair....
-
4.32.2 SEATING
If seating spaces for people in wheelchairs are provided at tables, counters, or work surfaces, clear floor space complying with 4.2.4 shall be provided....
-
One Set of Design Standards
A number of commenters objected to the fact that the proposed guidelines included more than one set of design standards....
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
Seats on diagnostic equipment used by patients in a seated position typically provide back and arm support for patient comfort and stability....
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool....
-
Jim Woods. Introductory Comments
The second would be criteria and design evaluations. In lighting, where are we today and how do we deal with these?...
- Bradley Partition Mounted Seat Cover Dispenser 582
- Bradley Surface Mounted Seat Cover Dispenser 5831
-
Use color and design to create architectural landmarks to aid in spatial orientation (slides 8 – 10)
We can use color and texture to facilitate wayfinding. We talked yesterday that thinking about it in terms of gray scale. For example, in the space on the left [in slide 8], there’s...
-
11B-216.2 Designations
Where pictograms are provided as designations of permanent rooms and spaces, the pictograms shall comply with Section 11B-703.6 and shall have text descriptors complying with Sections 11B...
-
§382.87 What other requirements pertain to seating for passengers with a disability?
[See subsections ...]
-
1.1.2
1.1.2 When a dimension range is the regulatory requirement use the midpoint of the range as the drawing dimension.