The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
Search Results "Recessed Button"
Commonly Searched Documents
-
11B-407.4.7.1.3 Symbols
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
Common Problem: Protruding Objects
The fountains shown in this photograph are recessed into an alcove to avoid the potential for injury. ...
-
Wall-Mounted Objects
Wing walls, side partitions, and alcoves or recesses can be used for elements such as drinking fountains with their bottom edges above 27 inches....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
Bobrick Recessed Sharp Disposal B-35016
Requires the Premium User plan or above. (Login or upgrade your account!)
-
American Specialties Recessed Shelf Model 0412
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-407.4.7.2 Keypads
Keypads shall be identified by characters complying with Section 11B-703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
- M-D Building Products, Inc. GEN3 SmartTool™ Digital Level
-
809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
FAQ: How do I enter a New CAD/BIM File in my Corada WorkSpace?
Adjust this setting by clicking the blue 'Edit' button to the right....
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit Resettable Combination Locks
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 7 Door High Unit Master Keyed Locks
-
809.5.5.1 Notification
A button or switch shall be provided outside the residential dwelling unit primary entrance....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
-
4.10.14* EMERGENCY COMMUNICATIONS
It shall be identified by a raised or recessed symbol and lettering complying with 4.30 and located adjacent to the device....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
407.2.2.3 Audible Signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1....