The clear floor space shall be positioned for parallel approach to the side of the bed....
Search Results "Parallel Approach"
Commonly Searched Documents
-
807.2.3 Beds
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
11B-807.2.3 Beds
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
1133A.2, Item 3
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by Section 1133A...
-
Landscape Forms Inc. Parallel 42 Bench Collection Video
Requires the Registered User plan or above. Login!
-
2.3 Use a Universal Design Approach
Explain that making the changes you need would be helpful for many of their members. 5 Here are some points you can use: Removing barriers could increase their...
-
1133A.2, Item 4
The centerline of the 30-inch (762 mm) by 48-inch (1219 mm) clear floor space provided for parallel or forward approach shall be aligned with the centerline of the work space, appliance...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
11B-504.4.1 Contrasting stripe
Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast....
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
Doorways without Doors or Gates, Sliding Doors, and Folding Doors: ADA Standard Section 404.2.4.2
Section 404.2.4.2 covers the current ADA Standards for maneuvering clearances at doorways without doors or gates, sliding doors, and folding doors.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS MINIMUM MANEUVERING CLEARANCE Approach...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...