413.1.2 Audio Description Controls (Section-by-Section Analysis) This proposed section would require that, where video-capable hardware provides controls for program selection, such ICT...
Search Results "Operable Part (Control)"
Commonly Searched Documents
-
413.1.2 Audio Description Controls (Section-by-Section Analysis)
-
413.1.2 Audio Description Controls
ICT shall provide user controls for the selection of audio description in at least one location that is comparable in prominence to the location of the user controls for program selection...
-
11B-411.4.7 Designations and indicators of car control buttons
Designations and indicators of car control buttons shall comply with Section 11B-411.4.7....
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
11B-411.2.1.4.2 Security or access controls
Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility....
-
4. Faucet Controls
Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
-
Restrooms Main Lobby
The handles, locks, and other operating devices of the men's and women's toilet stall doors do not have a shape that is easy to grasp with one hand and require tight grasping and twisting...
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons....
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
- Wagner Instruments Mark-10 M4 Digital Force Gauge
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
- Magnuson Group RIGA Series Waste Receptacle
-
§1193.41(i) Operable with limited cognitive skills
(i) Operable with limited cognitive skills. Provide at least one mode that minimizes the cognitive, memory, language, and learning skills required of the user....
-
11B-707.6.1 Input controls
At least one tactilely discernible input control shall be provided for each function....
-
§ 37.3 Small operator
Small operator means, in the context of over-the-road buses (OTRBs), a private entity primarily in the business of transporting people that is not a Class I motor carrier....
-
§1193.41(a) Operable without vision
(a) Operable without vision. Provide at least one mode that does not require user vision....
-
16) Elevator hoistway floor designations and car controls
16) Elevator hoistway floor designations and car controls ADAAG: Must have raised and brailled characters (§§4.10.5; 4.10.12)....
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
§ 38.23(b)(3) Emergency operation
(3) Emergency operation....
- Wagner Instruments Force Ten ™ FDX