The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
11B-405.7.2 Width
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-219.5 Permanent and portable systems
The California Building Code (CBC) requires permanently installed assistive listening systems in those assembly areas where audible communication is integral to the use of a space (movie...
-
11B-219.5 Permanent and portable systems
The California Building Code (CBC) requires permanently installed assistive listening systems in those assembly areas where audible communication is integral to the use of a space (movie...
-
11B-219.5 Permanent and portable systems
The California Building Code (CBC) requires permanently installed assistive listening systems in those assembly areas where audible communication is integral to the use of a space (movie...
-
Drinking Fountain Scoping for Exterior Sites
In the final rule, scoping has been clarified as applying to units provided at "exterior sites," in addition to those installed on floors....
-
Car Position Indicators [4.10.13]
Verbal announcements must announce each floor a car stops at but not each floor passed....
-
Stair widths
Section 1009.3 states that in order to be a part of the accessible means of egress between stories, stairs shall have a clear width of 48" BETWEEN the handrails....
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
Mark J. Mazz, AIA: Architectural Consultant on Accessibility
Measurable Design Criteria So, I get worried when things start getting written down, if they’re not clear and if they’re not measurable....
-
12101(b)(2)
(2) to provide clear, strong, consistent, enforceable standards addressing discrimination against individuals with disabilities;...
-
R407.6.3 Length
The landing clear length shall be 1.5 m (5.0 ft) long minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum....
-
11B-208.2.1 Hospital outpatient facilities
A local zoning code that requires a minimum number of parking spaces according to occupancy type and square footage may be an appropriate guide in assessing the number of spaces in the lot...
-
PATH OF TRAVEL
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms...
-
PATH OF TRAVEL
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms...
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
4.7.9.3 Height
The counter or rim of the sink shall be no more than 34 inches (865 mm) above the floor or ground....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...