[See subsections ...]
Search Results "Limited Access Space"
-
T604 Stowage
-
T211 Wheelchair Securement Systems
[See subsections ...]
-
608.2.2.1 Clearance
608.2.2.1 Clearance. A 30 inch (760 mm) wide minimum by 60 inch (1525 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. EXCEPTION:...
-
Sec.36.308(a)(1)(ii)(D)
(D) Permit individuals who use wheelchairs to sit with family members or other companions.
-
Detectable Warnings on Curb Ramps
[See subsections ...]
-
68.101(c)(5)(D) Toilet rooms or bathrooms
(D) If toilet rooms or bathrooms are required by the lease agreement or are provided to serve the leased area, at least one set of men's and women's toilet rooms or bathrooms or at...
-
Road Closure Drawings
This may be remedied by installing an accessible gate for wheelchair access (see figures 9 and 10) and replacing the road gate with a horse-friendly barrier (figure 11)....
-
Requirement 2 -- Public and Common Use Areas
[See subsections ...]
-
§100.205 Design and construction requirements.
[54 FR 3283, Jan. 23, 1989, as amended at 56 FR 11665, Mar. 20, 1991; 73 FR 63616, Oct. 24, 2008]
-
§100.205(e)
(e)
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
Are stairs in residential dwelling units covered by the Standards required to comply?
Yes, stairs that are part of a means of egress must comply in mobility accessible residential dwelling units covered by the Standards....
-
IV.B.2.
and 1:10, with a minimum character height (using an upper case “X”) of 1 inch for signs on the boarding side and a minimum character height of 2 inches for front “headsigns,” with “wide” spacing...
-
Typical Day One - Basic Facilities Requirements
ADA Design Standards (ADAAG) (2 - 3 hours) This graphic and photographic tour of the ADAAG includes, if requested, its relationship to ANSI A117.1 and UFAS, scoping issues, the “accessible...
-
Minimum Number of Accessible Parking Spaces
ADA Standards for Accessible Design 4.1.2(5) Total Number of Parking Spaces Provided (per lot) (Column A) Total Minimum Number of Accessible Parking Spaces (60" &...
-
§104.23(a) Design and construction
or part of a facility constructed by, on behalf of, or for the use of a recipient shall be designed and constructed in such manner that the facility or part of the facility is readily accessible...
-
1018.7.2 Cross Slope
This section requires the cross slope of beach access routes to not be steeper than 1:48....
-
6.7.2 Cross Slope
The cross slope of a beach access route shall be no more than 1:33 (3 percent)....
-
7. Commit to Ongoing Maintenance of Accessible Playground Surfaces as a Responsibility of Ownership
The accessibility standards require the minimum 30 x 48 inch clear floor space for transfer to/from the accessible play components to have a level surface with less than a 2.08 percent cross...
-
11B-1008.2.3 Water play components
Accessible routes serving water play components shall be permitted to use the exceptions in Section 11B-1008.2.3....
- Access Board: Exit Signs
-
Do facilities in remote locations have to be accessible?
If the Forest Service builds a facility, even in remote areas or areas that are difficult to access (including wilderness), the facility must be accessible, with few exceptions....
-
Recreation Site Layout
Accessibility is, of course, one of the many design parameters for any recreation site....