Beveled edges of frame hug mirror; provides gapless fit for improved appearance, and safety when cleaning mirror....
Search Results "NFSI: National Floor Safety Institute"
- Bobrick Fixed-Position Tilt Mirror B-293 1836
- Bobrick Fixed-Position Tilt Mirror B-293 1830
- AJW Architectural Products UJ16 Heavy Duty Hook
-
E.
Cinemark's auditoria with 300 seats or less, persons who use wheelchairs cannot access the seating on risers as the wheelchair spaces available to them are located on the traditional, sloped-floor...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. ...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-307.3.1 Edges and corners
Where signs or other objects are mounted on posts or pylons, and their bottom edges are less than 80 inches (2032 mm) above the floor or ground surface, the edges of such signs and objects...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
§ 38.107(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
§ 38.123(a)(3)
grab bar at least 40 inches long shall be mounted on at least one side wall, with one end not more than 12 inches from the back wall, at a height between 33 inches and 36 inches above the floor...
-
§ 38.159(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-902.4 Dining surfaces and work surfaces for children’s use
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground...
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
Miscellaneous Provisions
., Fourth Floor Washington, D.C. 20005. The e-mail or cover letter shall include a subject line referencing UPDC and DJ#204-33-117....
- Neo-Metro Metaal Toilet Configured for In-Wall Flushing System