Many codes require new buildings to have flashing strobe lights (visual devices) as part of the standard building alarm system, but because the requirements are not retroactive many buildings...
Search Results "Supplemental Requirement"
Commonly Searched Documents
-
Visual Devices for the Fire Alarm System
-
Many properties do NOT have enough electricity available to support significant charging installations, so for now, utilities and others are doing “make ready” spaces (upgrading the supporting infrastructure in a parking space for future use without adding the actual charger). How would make ready spaces comply with the ADA standards? Additionally, consider a site with 10 make ready spaces. Would the standards apply differently if that site has no chargers presently installed versus having one active charger installed?
It would be prudent for a designer to take into consideration the space requirements necessary for accessible EVCS based on the total projected number of EVCS planned for the site, in addition...
-
§27.19(a)
(a) Recipients subject to this part (whether public or private entities as defined in 49 CFR part 37) shall comply with all applicable requirements of the Americans with Disabilities Act...
-
Implementation Challenges for Interiors (slides 16 and 17)
Prescriptive requirements are great, [if they are] backed by research, but that also may limit the design creativity and options and force someone to design something somewhere that may...
-
907.2.9 Group R-2
Exceptions: A fire alarm system is not required in buildings not over two stories in height where all dwelling units and contiguous attic and crawl spaces are separated from each...
-
2. Section-by-Section Analysis of Final Guidelines
Section 3 reprints the text of 24 CFR 100.205, which implements the Fair Housing Act's accessibility requirements, and Section 4 describes the application of the Guidelines....
-
604.8.1.4 Toe Clearance
EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted...
-
221.2.3 Lines of Sight and Dispersion
When the number of wheelchair spaces required by 221.2.1 has been met, further dispersion shall not be required....
-
Noncomplying new construction and alterations. (Section-by-Section Analysis)
Section 36.406(a)(5) of the final rule sets forth the rules for noncompliant new construction or alterations in facilities that were subject to the requirements of this part....
-
Regulatory Flexibility Act (5 U.S.C. 601-612)
Moreover, as the text of the rule and preamble make clear, there are no retrofit requirements that would increase costs for covered entities, regardless of size, as requirements apply only...
-
E205.3 Agency Official Communication
Content that is not public facing shall conform to the accessibility requirements specified in E205.4 when such content constitutes official business, and is communicated by an agency through...
-
602.2 Accessibility and Compatibility Features
Documentation shall list and explain how to use the accessibility and compatibility features required by Chapters 4 and 5....
-
Bathrooms
If only half baths are provided, accessible fixtures are required in at least the one half bath required to be accessible....
-
II. REMEDIAL ACTION
The Parties agree that the technical requirements and, where appropriate, the scoping requirements of the Standards are used as a guide for determining whether a program or activity held...
-
Application [§201]
Requirements in the standards apply to both exterior and interior spaces and elements provided on a site, usually without distinction....
-
Handrails Along Walking Surfaces [§403.6, §505]
Handrails Along Walking Surfaces [§403.6, §505] Handrails are required at ramps with a rise greater than 6” and at stairs that are part of a means of egress, but not at other locations...
-
Noncomplying new construction and alterations. (Section-by-Section Analysis)
Section 35.151(c)(5) of the final rule sets forth the rules for noncompliant new construction or alterations in facilities that were subject to the requirements of this part....
-
5. Discussion of Proposed Standards
Although the standards do not impose any mandatory requirements on health care providers or medical device manufacturers, the standards use mandatory language (i.e., shall) because other...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
There is no requirement for providing gender pictograms in combination with the geometric identification symbols required at doorways leading to men’s, women’s and unisex toilet and bathing...
-
11B-208.1 General
Exception: Parking spaces used exclusively for buses, trucks, other delivery vehicles, or vehicular impound shall not be required to comply with Section 11B-208 provided that lots accessed...
-
11B-223.2.2 Facilities specializing in treating conditions that affect mobility
Conditions that affect mobility include conditions requiring the use or assistance of a brace, cane, crutch, prosthetic device, wheelchair, or powered mobility aid; arthritic, neurological...
-
11B-807.2 Cells with mobility features
Cells required to provide mobility features shall comply with Section 11B-807.2....
-
§382.143(a)
(a) As a U.S. carrier, you must meet the training requirements of §382.141 by the following times....
-
F215.4 Transient Lodging
Guest rooms required to comply with F224.4 shall provide alarms complying with 702....