Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
Search Results "Floor-Level Exit Sign"
-
4.4.1* GENERAL
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
23. Q: What types of modifications in law enforcement policies, practices, and procedures does the ADA require?
cells excet at scheduled intervals, in order to accommodate an individual with diabetes who uses medication and needs access to carbohydrates or sugar to keep blood sugar at an appropriate level...
-
11B-608.5.3 Alternate roll-in type shower compartments
The controls, faucets, and shower spray units shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor....
-
BHMA
Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017 A 156.10-2017: Power Operated Pedestrian Doors 1010.3.2, 11B-404.2.9, 11B-404.3...
-
11B-608.5.3 Alternate roll-in type shower compartments
The controls, faucets, and shower spray units shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor....
-
BHMA
Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017 A 156.10-2022: Power Operated Pedestrian Doors 1010.3.2, 11B-404.2.9, 11B-404.3...
-
Audible Hall Signals
Comments recommended that the minimum be changed to 10 decibels above the ambient noise level for consistency with the ANSI A117.1‒2003 standard. Response....
-
F104.1.1 Construction and Manufacturing Tolerances
Where the requirement states a specified range, such as in 609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance...
-
18 Inch Low Height
He also stated there is limited data on the effect of a level change as the distance (gap) between the wheeled mobility device and the piece of medical equipment increased and cautioned...
-
POWER DISRUPTION
Various agencies and utility companies coordinate efforts to reduce load levels and identify and help affected populations....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Signs. 3. ...
- EZ-ACCESS Transitions® Modular Entry Mat
- Sizewise Evolution
- EZ-ACCESS Transitions® Angled Entry Mat
-
Value Contrast (slide 9)
But then it matches the value on the floor. So it causes a problem....
- SafePath Courtedge™ Reducer Ramps
-
§ 36.401(d)(3)
For example, in a facility that houses a shopping center or shopping mall, or a professional office of a health care provider, the floors that are above or below an accessible ground floor...
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
711.4.1.2 Through-penetration firestop system
The system shall have an F rating and a T rating of not less than 1 hour but not less than the required rating of the floor penetrated....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Sec.36.401(d)(3)
For example, in a facility that houses a shopping center or shopping mall, or a professional office of a health care provider, the floors that are above or below an accessible ground floor...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....