Destination-oriented elevators are different from typical elevators in that they provide a means of indicating the desired floor at the location of the call button, usually through a key...
Search Results "Floor-Level Exit Sign"
-
Destination-Oriented Elevators
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
Obstructed High Reach: ADA Standard Section 308.2.2
Section 308.2.2 covers the current ADA Standards for obstructed high reach.
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
11B-411.2.1.7.3 Assignment by security credential
Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
-
Play Tables: ADA Standard Section 1008.4.3
EXCEPTION: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
Scoping [4.1.3(10)]
Instead it requires access based on the number provided on each floor so that half (50%) are accessible to people who use wheelchairs....
-
Dispersion
For example, if a floor is occupied by separate tenancies, both types of units should be dispersed to serve occupants of each tenancy....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
III-7.5140 Drinking fountains
Where there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to those who have difficulty bending or stooping (for example, by...
-
Expert Report of Douglas J. Anderson, RAS, CASP, LCM Architects (August 8, 2018)
pedestrian route from the entrance to the voting area contains a suggestion box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor...
-
503.4.2 Audio Description Controls
Where user controls are provided for program selection, ICT shall provide user controls for the selection of audio descriptions at the same menu level as the user controls for volume or...