The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
11B-504.5 Nosings
-
11B-504.5 Nosings
The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....
-
11B-1009.2.7 Operation
It is extremely important for a person who is swimming alone to be able to call the pool lift when it is in the up position so he or she will not be stranded in the water for extended periods...
-
12162(a)(4)(B)(ii)
(ii) appropriate auxiliary aids and services, including a hard surface on which to eat, shall be provided to ensure that other equivalent food service is available to individuals with disabilities...
-
7.4.4.3 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
A4.13.8 Thresholds at Doorways
Thresholds and surface height changes in doorways are particularly inconvenient for wheelchair users who also have low stamina or restrictions in arm movement because complex maneuvering...
-
2.8 Openings
Openings in the surface of ORARs shall be small enough to prevent passage of a 1/2 inch (13 mm) diameter sphere....
-
A4.13.8 THRESHOLDS AT DOORWAYS
Thresholds and surface height changes in doorways are particularly inconvenient for wheelchair users who also have low stamina or restrictions in arm movement, because complex maneuvering...
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided...
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
§8.25(c) Existing public housing and multi-family Indian housing—needs assessment and transition plan
The Assistant Secretary for Fair Housing and Equal Opportunity and the Assistant Secretary for Public and Indian Housing may extend the four year period for a period not to exceed two years...
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
Within dormitories in housing at a place of education, dormitory floors served by an accessible route and providing only sleeping rooms complying with 11B-809.6, and where bathrooms are...
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
Finish and Contrast [4.30.5]
Consideration should also be given to light sources and the ambient lighting to prevent glare on sign surfaces....
-
Roughness Measurement
The surface profiles were measured with a custom-built pathway measurement tool (PathMeT), which was created from a power WC frame that was instrumented with a wheel encoder and an Acuity...
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
M102.1 Defined Terms
The following terms are defined in the proposed standards: Enforcing authority, medical diagnostic equipment, operable parts, and transfer surface....
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
Upon further consideration, however, the Department has concluded that the regulation should acknowledge that there are times when there are transitions from sidewalk to road surface that...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
§ 38.159(c)(8) Handrails
grasp them from outside the vehicle while starting to board, and to continue to use them throughout the boarding process, and shall have the top between 30 inches (760 mm) above the ramp surface...
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...