The models were installed at 39 inches above finished floor to the base....
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
Height
-
5.1.4 Turning Space
Where the camp shelter floor is not elevated above the trail or ORAR, a turning space complying with ABAAS section 304.3 shall be provided....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
Joint Plan Certification II
Joint Plan Certification II This is to certify that (name of entity covered by joint plan) will, in accordance with 49 CFR 37.141, maintain current levels of paratransit service until...
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
- Murdock Manufacturing Waterless Toilet Riser with Seat and Cover
- Kompan, Inc. Miram GXY926
- Guardian Barrier-Free Eyewash: Deck Mounted, AutoFlow™ 90º Swing-Down GBF1849
- ADA-100® Area of Refuge Communication System
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
F206.2.3.1 Stairs and Escalators in Existing Buildings
an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an accessible route shall be provided between the levels...
-
206.2.3.1 Stairs and Escalators in Existing Buildings
an escalator or stair is provided where none existed previously and major structural modifications are necessary for the installation, an accessible route shall be provided between the levels...
-
11B-406.5.8 Counter slope
The adjacent surfaces at transitions at curb ramps to walks, gutters, and streets shall be at the same level....
-
§ 38.71(b)(2)
(2) Vehicles designed for, and operated on, pedestrian malls, city streets, or other areas where level boarding is not practicable shall provide wayside or car-borne lifts, mini-high platforms...
-
1.14 Riser
1.14 "Riser" shall mean and refer to an elevated tier (usually six to eighteen inches) in an auditorium on which seats are affixed to the auditorium floor....
-
4. Toilet seat height
Toilet seat height: The toilet seat needs to be from 17 to 19 inches above the floor to permit transfers to and from wheelchairs....
-
Question 20
Is the required floor and wall space inside public restrooms and fitting rooms blocked by obstacles such as trash cans, chairs, or shelving?...
-
J3
Is the top of the spout no higher than 36 inches above the floor and at the front of the fountain or water cooler? [ADA Standards § 4.15.2] Yes No...
-
I. Toilet Seat
Is the toilet seat at each accessible toilet between 17"-19" above the floor? [ADA Stds. 4.16.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
e-vii
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Standards § 4.10.13] Yes No...