[See subsections ...]
Search Results "Tactile Exit Signage"
Commonly Searched Documents
-
F207 Accessible Means of Egress
-
11B-207 ACCESSIBLE MEANS OF EGRESS
[See subsections ...]
-
11B-207 Accessible means of egress.
[See subsections ...]
-
11B-207 Accessible means of egress
[See subsections ...]
-
Talking three-dimensional models for way-finding and orientation
Talking three-dimensional models for way-finding and orientation Touchable models provide more spatially accurate information than the simple raised line map. A three dimensional...
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...
-
Route and Destination Signs
The Board has removed as unnecessary the exception for signs not essential to the use of the transit system, such as exit street names....
- Takeform Fusion Signage Miscellaneous Room Identification Type E.3
-
Pictogram Field: ADA Standard Section 703.6.1
Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field.
-
Braille: ADA Standard Section 703.3
Braille shall be contracted (Grade 2) and shall comply with 703.3 and 703.4.
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities. The text of the room identification sign shall be “ADULT...
-
11B-703.3 Braille
Braille shall be contracted (Grade 2) and shall comply with Sections 11B-703.3 and 11B-703.4. Advisory 11B-703.3 Braille. Contracted Braille uses special characters called...
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
Sign
NOTES Sign Clarification of terminology regarding accessibility requirements for “signs” as individual building elements as opposed to “signage...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
Men’s toilet and bathing facilities shall be identified by an equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward. The...
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
Women’s toilet and bathing facilities shall be identified by a circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter. The circle symbol shall contrast with the door,...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
Unisex toilet and bathing facilities shall be identified by a circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter with a ¼ inch (6.4 mm) thick triangle with a vertex...
-
Which Paths Lead to Usable Circulation Paths?
Any circulation paths that are not usable should include signs directing people to other, usable paths. People with limited mobility should be provided with written directions, a...
-
11B-703.7.2.6.4 Edges and corners
Edges of signs shall be rounded, chamfered or eased. Corners of signs shall have a minimum radius of 1/8 inch (3.2 mm).
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
11B-703.7.2.6.4 Edges and vertices on geometric symbols. Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum. Vertices shall be...
-
11B-703.7.2.6.4 Edges and vertices on geometric symbols
Edges shall be eased or rounded at 1/16 inch (1.59 mm) minimum, or chamfered at 1/8 inch (3.2 mm) maximum. Vertices shall be radiused between 1/8 inch (3.2 mm) minimum and ¼ inch...
-
1010.2.13.1 Delayed egress locking system
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...
-
11B-407.4.9 Emergency communication
Tactile symbols and Characters shall be provided adjacent to the device and shall comply with 703.2....