Transfer supports, stirrups, and reclining surfaces shall comply with M301.3.
Search Results "Table Height"
Commonly Searched Documents
-
M301.3 Supports
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and maximum vertical height...
- American Specialties 9018 Recess Mounted Stainless Steel Horizontal Baby Changing Station
-
Raised Characters
Specifications for raised characters in section 703.2 address the depth, case, style or font type, character proportion and height, stroke thickness, and character and line spacing....
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
The standards for medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables...
-
Picnic Unit
An outdoor space within a picnic area or facility that is designed and constructed for picnicking and that contains one or more constructed features such as picnic tables, grills, and other...
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
11B-703.8.4 Character height
11B-703.8.4 Character height. The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
-
11B-703.8.4 Character height
11B-703.8.4 Character height. The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum.
- Figure 904.3.2 Check-Out Aisle Counters – Drawing from the U.S. Access Board
-
11B-703.8.4 Character height
The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font....
-
11B-604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat....
-
Line Spacing: ADA Standard Section 703.2.8
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
- American Specialties 9014 Surface Mounted Horizontal Baby Changing Station
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment
The standards for medical diagnostic equipment (MDE Standards) contain minimum technical criteria to ensure that medical diagnostic equipment, including but not limited to, examination tables...
-
4.1.1 Range of Examination Table and Chair Configurations
4.1.1 Range of Examination Table and Chair Configurations Examination tables and chairs are used wherever patients are examined throughout the health care delivery system....
-
CHAPTER 9: BUILT-IN ELEMENTS
CHAPTER 9: BUILT-IN ELEMENTS
- American Specialties 9013 Recessed Stainless Steel Baby Changing Station
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor. Provide a clearance of at least 29 in (735 mm) above the finish...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor. Provide a clearance of at least 29 in (735 mm) from the floor to...