Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
Search Results "Segment Length"
Commonly Searched Documents
-
705.2 Platform Edges
-
810.5.2 Detectable Warnings
Platform boarding edges not protected by platform screens or guards shall have detectable warnings complying with 705 along the full length of the public use area of the platform....
-
Handrail Extensions [§505.10]
The length is measured to the start of the return radius....
-
Accessible Route
This suggested approach would be an alternative to the gangway length exceptions and limits in section 1003.2.1 of the 2010 Standards....
-
R208 Detectable Warning Surfaces (Section-by-Section Analysis)
travel because detectable warning surfaces must extend 610 millimeters (2 feet) minimum on each side of the island and be separated by a 610 millimeters (2 feet) minimum length of island...
-
Sections 4.8.5 and 4.9.4
Section 505.6 requires handrail gripping surfaces to be continuous along their length and not to be obstructed along their tops or sides....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Handrails
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops and sides....
-
Mirrors [4.19.6]
Recommendations:Full-length mirrors that extend up to standard height (74 inches minimum recommended) are a good idea because they serve a broader range of people, including those of short...
-
1016.8 Resting Intervals
This section contains the technical requirements for the length (1016.8.1), width (1016.8.2), and slope (1016.8.3) of resting intervals; and for a turning space (1016.8.4) where resting...
-
11B-705.1.2.1 Platform edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform....
-
Trailhead Information Signs [F216.13 and 1017.10]
The new trail information signs must include the following information: Length of the trail or trail segment Type of trail surface Typical and minimum trail tread...
-
Providing Appropriate Information About Accessibility
accessibility guidelines or not, include the following trail information, in addition to other information typically provided for hikers, on trailhead signs: Destination and length...
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
B7-b
[ADA Standards § 4.7.2] Yes No Note: 1:12 is one inch of vertical height for each 12 inches of length....
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
E1-1. Accessible Route
Is there an accessible route, at least 36 inches wide that connects the accessible entrance to the voting area (the accessible route may narrow to 32 inches wide for up to 2 feet in length...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
809.2.2 Turning Space
However, the overlap of turning space must be limited to one segment of the T-turn so that back-up maneuvering is not restricted....
-
809.2.2 Turning Space
However, the overlap of turning space must be limited to one segment of the T-turn so that back-up maneuvering is not restricted....
-
809.2.2 Turning Space
However, the overlap of turning space must be limited to one segment of the T-turn so that back-up maneuvering is not restricted....
-
D. Recording, Categorizing, and Reporting Written Disability-related Complaints Received by Carriers
[Sec. 382.70(c)] 1 Foreign carriers are covered by this section only with respect to disability-related complaints associated with any flight segment originating or terminating in the...
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The bottom of the transfer support shall have no obstruction affecting more than 20% of its length....
-
R409.3 Continuity
Handrails shall be continuous within the full length of each ramp run or stair flight....