The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
Search Results "Non-Positive Shut Off"
-
M301.2.2 Size
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
11B-206.2.1 Site arrival points
At least one accessible route shall be provided within the site from accessible parking spaces and accessible drop-off and passenger loading zones; public streets and sidewalks; and public...
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the seated position...
-
5.7.1 Lift Compatibility Clearance in Base for M301
lifts to be effective, they must deploy at diagnostic equipment such that the boom of the lifts can maneuver far enough over the equipment to safely lower and raise the patient onto and off...
-
1008.2.5.3.1 Handrail Gripping Surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
1008.2.5.3.1 Handrail Gripping Surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface....
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
1008.2.5.3.1 Handrail Gripping Surfaces
Where the shape of the gripping surface is non-circular, the handrail shall provide an equivalent gripping surface...
-
5.2.2.2 Transfer Surface Depth Recommendation for M302
5.2.2.2 Transfer Surface Depth Recommendation for M302 The Committee recommends a minimum depth requirement of 17 inches for equipment used by patients in seated positions....
-
Standing Supports (M304.3 and M305.3)
Standing supports can be provided in a horizontal position, vertical position, or a combination of horizontal and vertical positions, as long as the minimum length of gripping surface is...
-
5.2.2.1 Transfer Surface Width Recommendations for M302
Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily used by patients in a seated position...
-
Pool Lifts
Pool Lifts
-
T604 Stowage
[See subsections ...]
-
T704.3 Automated Announcement Systems
Automated systems for stop announcements and route identification announcements shall comply with T704.3.
-
T211 Wheelchair Securement Systems
[See subsections ...]
-
T211 Wheelchair Securement Systems
Wheelchair securement systems complying with the technical requirements in T603 must be provided at each wheelchair space. The Access Board received several comments on the proposed...
-
B. Legal foundation for equipment and furniture coverage
B. Legal foundation for equipment and furniture coverage The ADA prohibits discrimination on the basis of disability in all services, programs, and activities offered by public...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish....
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish....