An elevator to be considered part of an accessible means of egress shall comply with the emergency operation and signaling device requirements of Section 2.27 of ASME A17.1....
Search Results "Means of Egress Signage"
Commonly Searched Documents
-
1007.4 Elevators
-
TTYs: ADA Standard Section 216.9
Section 216.9 covers scoping requirements in the current ADA Standards for signs for TTYs.
-
11B-502.6.1 Finish and size
Parking identification signs shall be reflectorized with a minimum area of 70 square inches (45,161 mm2).
-
11B-216.9 TTYs
Identification and directional signs for public TTYs shall be provided in accordance with Section 11B-216.9.
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
A circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter, shall be located at entrances to women’s toilet and bathing facilities. The circle symbol shall contrast with the...
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
An equilateral triangle, ¼ inch (6.4 mm) thick with edges 12 inches (305 mm) long and a vertex pointing upward, shall be located at entrances to men’s toilet and bathing facilities....
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
- Takeform Fusion Signage Floor Directional Type B
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
International Symbol of TTY: ADA Standard Section 703.7.2.2
The International Symbol of TTY shall comply with Figure 703.7.2.2.
-
11B-210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. Exceptions: 1. ...
-
11B-210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. Exceptions: 1....
-
11B-210.1 General
Interior and exterior stairs that are part of a means of egress shall comply with 504. Exceptions: 1....
-
Two-way Communication [4.3.11.4]
The two-way communication system must be equipped with both audible signals (for people with vision impairments) and visual signals (for people with hearing impairments) and cannot...
- Takeform Fusion Signage Floor Directional Type B.2
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
Signage
Signage Common Problem: For permanent rooms and spaces, identification signage is mounted in the wrong location and cannot be read by persons who are blind or have low vision....
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5. Where pictograms are provided as...
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...