Alterations to Accessible Units, Sleeping Rooms, and Suites [9.1.5]
-
Guest Rooms
Reminder: The requirement for mobility accessible rooms and hearing-impaired accessible rooms are separate requirements allowing for minimal overlap. 806.3 Guest Rooms with Communication...
-
11B-213.3.7 Coat hooks and shelves
Where coat hooks or shelves are provided in toilet rooms without toilet compartments, at least one of each type shall comply with Section 11B-603.4....
-
11B-213.3.7 Coat hooks and shelves
Where coat hooks or shelves are provided in toilet rooms without toilet compartments, at least one of each type shall comply with Section 11B-603.4....
-
224.4 Guest Rooms with Communication Features
224.4 Guest Rooms with Communication Features....
-
806.2.4.1 Vanity Counter Top Space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
806.2.4.1 Vanity Counter Top Space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
F224.4 Guest Rooms with Communication Features
In transient lodging facilities, guest rooms with communication features complying with 806.3 shall be provided in accordance with Table F224.4....
-
Toilet Rooms South (Briefing Theater)
Toilet Rooms South (Briefing Theater): jj....
-
224.4 Guest Rooms with Communication Features
In transient lodging facilities, guest rooms with communication features complying with 806.3 shall be provided in accordance with Table 224.4....
-
806.2.4.1 Vanity Counter Top Space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM
Washington, DC: Access Board Conference Room, 1331 F Street, NW., Suite 800, Washington, DC 2004. 2....
-
L. Accessible Guest Rooms
Accessible Guest Rooms (1) Defendants will have 12 designated accessible rooms/ suites that comply with the 2010 Standards dispersed among the various classes of accommodations as follows...
-
Section 1630.14(c) Examination of Employees
Section 1630.14(c) Examination of Employees This provision permits employers to make inquiries or require medical examinations (fitness for duty exams) when there is a need to determine...
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the...
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2.
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed...