1.3.1 Need for Detectable Warnings at Curb Ramps For pedestrians who have visual impairments, curbs used to be a reliable cue for detecting the boundary between the sidewalk and a street...
Search Results "Curb Ramp Slope"
Commonly Searched Documents
-
1.3 Previous Research
-
11B-403.3 Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
11B-403.3 Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
-
4. Access to Newly Constructed and Altered Facilities
In addition, the City will upgrade noncompliant curb ramps and/or install new curb ramps where existing ramps are lacking in connection with street resurfacing and repaving and other major...
-
810.5.1 Slope
810.5.1 Slope. Rail platforms shall not exceed a slope of 1:48 in all directions....
-
810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
10.2.1(1)
(1) Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96...
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
406.2 Counter Slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20....
-
1015.6 Slope
This section requires the slope of the surface of the clear ground space and turning space to not be steeper than 1:48 in any direction....
-
§ 38.95(b)(8) Platform entrance ramp
(8) Platform entrance ramp....
-
Re: Husky 24" Line Generator Digital Laser Level
See Bill Hecker, AIA, Kirola vs City and County of San Francisco, Expert for DOJ, testimony with regards to Laser level lengths.
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
4.21.7 Curbs
4.21.7 Curbs. All of the designs reviewed were curbless, roll-in showers....
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
1. Public Right-of-Way
In addition, Kirola's experts measured curb ramp slopes without considering the ramp's overall "rise in run" and flatness. RT 2056:10-2057:1....
-
Temporary Suspension
Temporary Suspension In response to business and user concerns about the need for the detectable warnings specified in 4.29 at curb ramps and hazardous vehicular areas, the Access Board...
-
68.10(10) Curb Line
(10) Curb Line--A line that represents the extension of the face of the curb and marks the transition between the sidewalk and the gutter or roadway at a curb ramp or flush landing....
-
R304.5.1.2 Shared Use Paths
In shared use paths, the width of curb ramps runs and blended transitions shall be equal to the width of the shared use path....
-
2.5.4 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
Accessible Slopes
For a ramp the maximum running slope allowed is 1:12. That means for every inch of height change there should be at least 12 inches of ramp run....