The magic of 3D depth sensing begins with the ability to capture fast, accurate, dimensions of objects and environments....
Search Results "Counter Depth"
Commonly Searched Documents
- Structure Sensor 3D Depth Scanning Software for 3D Imaging and Printing
-
306.3.2 Maximum Depth
306.3.2 Maximum Depth. Knee clearance shall extend 25 inches (635 mm) maximum under an element at 9 inches (230 mm) above the finish floor or ground....
-
11B-306.3.3 Minimum required depth
At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth of 8 inches (203 mm...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
11B-306.3.3 Minimum required depth
Exceptions: At lavatories required to be accessible by Section 11B-213.3.4, the knee clearance shall be 27 inches (686 mm) high minimum above the finish floor or ground at a depth...
-
1. Abdomen depth (AD)
Abdomen depth (AD) Abdomen depth was analyzed as the overall clearance depth beneath the mammography machine, and measured from the anterior-most aspect of the abdomen to the anterior-most...
-
806.2.4.1 Vanity Counter Top Space
806.2.4.1 Vanity Counter Top Space....
-
1009.4.3 Wall Depth and Length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
11B-802.1.3 Depth
Advisory 11B-802.1.3 Depth. Figure 11B-802.1.3 (b) depicts a single wheelchair space with side entry....
-
806.2.4.1 Vanity Counter Top Space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
806.2.4.1 Vanity Counter Top Space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.) (1) 30" minimum countertop space for sink installation with...
-
1133A.1 General
Kitchens shall be on an accessible route and shall comply with this section. (See Figure 11A-10A.)
- Bosch Five-Point Self-Leveling Alignment Laser GPL 5 S
- Bosch 3-Point Self-Leveling Alignment Laser GPL 3
- Bosch 3 Point Self Leveling Alignment Laser Level GPL 3 S
-
Re: Service Counters
other side of the counter....
-
5.2.2.2 Transfer Surface Depth
5.2.2.2 Transfer Surface Depth. The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
M303.2.3 Depth (Section-by-Section Analysis)
The MDE Advisory Committee did not make recommendations regarding the general requirement for depth for wheelchair spaces, but did make recommendations regarding the depth of wheelchair...
-
3.3.8 Knee Clearance Depth, minimum
3.3.8 Knee Clearance Depth, minimum Knee clearance depths for the four sets of standards range from 200 mm (8 in.) in Canada to 280 mm (11 in.) in the U.S. (Figure 3‒8)....
-
3.3.9 Toe Clearance Depth, minimum
3.3.9 Toe Clearance Depth, minimum Toe clearance depths for the standards range from 150 mm (6 in.) in the U.S. to 230 mm (9 in.) in Canada (Figure 3‒9)....
-
5.2.1.2 Transfer Surface Depth
5.2.1.2 Transfer Surface Depth....
-
R405.2.3 Minimum Required Depth
R405.2.3 Minimum Required Depth. Where toe clearance is required at an element as part of a clear space, the toe clearance shall extend 430 mm (1.4 ft) minimum under the element....