Slope, width and headroom of all interior accessible routes. 11B-402 Door opening widths. 11B-404 Maneuvering clearances...
Search Results "Continuous Width"
Commonly Searched Documents
-
Verify Framing
-
Verify Framing
Slope, width and headroom of all interior accessible routes. 11B-402 Door opening widths. 11B-404 Maneuvering clearances...
-
1003.2.13.7.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
11B-226.4 Baby diaper changing station
Baby diaper changing stations when deployed shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
11B-224.1.2 Guest room doors and doorways
into and within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall comply with Section 11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width...
-
11B-224.1.2 Guest room doors and doorways
into and within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall comply with Section 11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width...
-
4(1)
(1) A minimum clear width of 36 inches is provided....
-
§ 38.95(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
11B-226.4 Baby changing tables
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
1003.2.13.2 Enclosed stairways
An enclosed stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area...
-
224.1.2 Guest Room Doors and Doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
F224.1.2 Guest Room Doors and Doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
224.1.2 Guest Room Doors and Doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
General: ADA Standard Section 307.1
Section 307.1 of the ADA Standards covers information in the current ADA Standards for protruding objects.
-
Protruding Objects: ADA Standard Section 204
Section 204 covers the scoping requirements of general exceptions for protruding objects in the most current ADA Standards
-
Protruding Objects: ADA Standard Section 307
Section 307 covers the current ADA Standards for protruding objects.
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
11B-204 Protruding objects
[See subsections ...]
-
11B-307.1 General
Protruding objects shall comply with Section 11B-307.
-
11B-307 Protruding objects
[See subsections ...]
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....