F104.1.1 Construction and Manufacturing Tolerances
-
11B-104.1.1 Construction and manufacturing tolerances
Where the requirement states a specified range, such as in Section 11B-609.4 where grab bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate...
-
Re: Section 307 Protruding Objects
Could you please direct me to the section in the code indicates that an 8" deep shelf at 40"-48" AFF is code compliant as stated? Thank you in advance!
-
Re: Section 307 Protruding Objects
Hi Justin, Sorry I didn't see you question sooner. See ADAS 603.4 and CBC 11B-603.4. The (maximum) depth of a shelf isn't noted, but you're unlikely to find many shelves less...
-
Water Hydrants
Standard handpumps require a force greater than 5 pounds (2.2 newtons) and a long reach to operate....
-
104.1.1 Construction and Manufacturing Tolerances
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
104.1.1 Construction and Manufacturing Tolerances
All dimensions are subject to conventional industry tolerances except where the requirement is stated as a range with specific minimum and maximum end points....
-
Clear Floor Space [§309.2]
This facilitates access since the forward reach does not extend beyond a wheelchair user’s toes....
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
Forward Approach
An existing exception for units designed specifically for children’s use permits a parallel approach if certain criteria for spout height and location are met....
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
Height: ADA Standard Section 902.4.2
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground.
-
Handrails [§504.6, §505]
Stairway Handrails Recommendation: In facilities that primarily serve children, a second set of stairway handrails 28” high maximum above stair nosings is advisable....
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
- Pilot Rock Smoker's Cease Fire Ash Receptacle
-
11B-609.4 Position of grab bars
in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children's...
-
11B-609.4 Position of grab bars
in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children's...
-
11B-604.9.2 Clearance
Clearance around a water closet shall comply with Section 11B-604.3.
-
604.9.3 Height
The height of water closets shall be 11 inches (280 mm) minimum and 17 inches (430 mm) maximum measured to the top of the seat. Seats shall not be sprung to return to a lifted...
-
604.9.2 Clearance
Clearance around a water closet shall comply with 604.3.
-
604.9.7 Toilet Compartments
Toilet compartments shall comply with 604.8.
-
11B-604.9.3 Height
The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat. Seats shall not be sprung to return to a lifted...
-
11B-604.9.7 Toilet Compartments
Toilet compartments shall comply with Section 11B-604.8.