In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
Search Results "Floor Surface"
Commonly Searched Documents
-
4.17.4 Toe Clearances
-
Height [4.18.2]
Height [4.18.2] The rim of an accessible urinal must be no higher than 17 inches above the finished floor....
-
4.17.4 TOE CLEARANCES
In standard stalls, the front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
1134A.7, Item 4
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
-
§ 38.79(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
§ 38.117(b)
(b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
11B-903.6 Structural strength
Benches shall be affixed to the wall or floor....
-
§ 38.99(b)
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm) on floors...
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION...
-
R409.10.3 Bottom Extension at Stairways
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
R409.10.2 Top Extension at Stairways
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
-
SHOPPING CENTER (OR SHOPPING MALL)
A shopping center may include a series of buildings on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership...
-
Feminine product dispensers
For purposes of resolving this matter, the Museum will provide, on each floor, at least one feminine product dispenser in the women's toilet rooms that does not requires tight grasping and...