In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
11B-804.2.1 Pass through kitchen
-
1015.2 Clear Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
704.5 Fire-resistance rating
The fire-resistance rating of exterior walls with a fire separation distance of 5 feet (1524 mm) or less shall be rated for exposure to fire from both sides....
-
J2
If the drinking fountain is a floor-mounted unit, is there clear floor space at least 30 inches long x 48 inches wide (60 inches if it is in an alcove) for a side approach to the drinking...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension "x" in Fig. 25) if the door is at...
-
Spout Location [4.15.3]
Spout Location [4.15.3] A person using a wheelchair has limited ability to lean over a drinking fountain, especially from a side approach....
-
4.7.6 Water Hydrant Clear Floor or Ground Space
Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
-
1015.2 Clear Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap an outdoor recreation access route or trail, as applicable, or another clear ground space....
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and 0-16...
-
2. Mirrors
Mirrors: If provided, mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor....
-
705.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. Figure 705.1 Size and Spacing of Truncated Domes...
-
Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
Confirm that the vibrotactile indications work
Confirm that the vibrotactile indications work The tactile arrow or vibrating surface should vibrate rapidly only during the walk interval for the street....
-
R305.2.6 Boarding Platforms
At boarding platforms for buses and rail vehicles, detectable warning surfaces shall be placed at the boarding edge of the platform....
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2. ...
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2....
- Assisted Living Directory - South Carolina Assisted Living Facilities & Senior Care
-
11B-405.9.2 Curb or barrier
or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground surface...
-
Openings [1016.6]
Openings are gaps in the surface of an ORAR....
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....