Where the central control point is not a constantly attended location, a two-way communication system shall have a timed automatic telephone dial-out capability to a monitoring location....
Search Results "Regarded as Having an Impairment"
-
1009.8.1 System requirements
-
§ 37.9(c)(1)
(1) New construction or alterations of buildings or facilities on which construction has begun, or all approvals for final design have been received, before November 29, 2006, are not required...
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48....
-
11B-407.2.1 Call controls
[2010 ADA Standards] EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
1.1.10 Availability of codes
Each state department concerned and each city, county or city and county shall have an up-to-date copy of the code available for public inspection, See Health and Safety Code Section 18942...
-
Auditorium accessible seating
So if you have a wheelchair occupying the end floor space, one row of seats has only one way out and the other forward row may not even have the required 12” minimum clearance in front of...
-
Parking
percent of total 1001 and over 20, plus 1 for each 100, or fraction thereof, over 1000 Small businesses with very limited parking (four or fewer spaces) must have...
-
Vanity Counter Tops
Requirements for accessible toilet and bathing rooms include a provision for vanity counter top spaces, which in the past have been omitted from accessible guest rooms even where provided...
-
E203.2 Agency Business Needs (Section-by-Section Analysis)
The Board intends, through this provision, to reinforce the fundamental principle that agencies have an affirmative, continuing obligation under Section 508 to maintain the accessibility...
-
Curb Ramps at Marked Crossings and Vehicular Lanes
In the final rule, requirements for the general location of curb ramps that were provided at [DOT ADA Standards] section 406.8 in the proposed rule have been integrated into this provision...
-
Scoping Requirements for Elevators
Scoping provisions have been editorially revised to correspond to reorganized technical criteria in Chapter 4....
-
d. Problem: Videos and Other Multimedia Lack Accessible Features
On the other hand, persons who are blind or have low vision are frequently unable to see the video images but can hear the audio track....
-
F206.2.5 Restaurants and Cafeterias
In sports facilities, tiered dining areas providing seating required to comply with F221 shall be required to have accessible routes serving at least 25 percent of the dining area provided...
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
C. Needs of Individuals with Chemical and Electrical Sensitivities
The advisory committee discussed issues related to the indoor environmental quality of emergency transportable housing units, but the committee concluded that it did not have the expertise...
-
"Minimal protection." (Section-by-Section Analysis)
., alerting and protecting a person who is having a seizure). Despite the Department's best efforts, the minimal protection language appears to have been misinterpreted. ...
-
School Districts' Standards and Procedures
School districts must have standards and procedures to evaluate students who may have a disability and need special education or related services.54 The evaluation of a student, however,...
-
711.3.2 Membrane penetrations
Where walls and partitions are required to have a minimum 1-hour fire-resistance rating, recessed fixtures shall be installed such that the required fire resistance will not be reduced....
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-