sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor...
Search Results "Ground Floor Exit"
-
11B-809.9.3 Removable base cabinets
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
- Cybex Total Access Upright Bike
-
405.2 Slope (Exception 2), 405.6 Rise (Exception)
The floor level of emergency transportable housing units is typically elevated 36 inches above the ground....
-
Site Selection
Facilities that have ground floor meeting rooms with accessible paths directly to the outside are also preferable, as this may allow greater numbers of individuals to evacuate independently...
- Unity Surfacing Systems Soft-Land Rubberized Safety Surfacing
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
ACCESSIBLE ROUTE
Interior accessible routes may include corridors, hallways, floors, ramps, elevators and lifts....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
MEASUREMENT TECHNIQUE
MEASUREMENT TECHNIQUE The depth and width are measured along the centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth...
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
E2-c
Remove or relocate the object or place a detectable object on the floor below each object to remove the hazard....
-
406.4.1 Clear height
The clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than 7 feet (2134 mm). Advisory 406.4.1 Clear height. ...
-
604.8.1.6 Lavatory
The lavatory shall be mounted so as not to overlap the clear floor space areas required by section 604 for the wheelchair accessible toilet compartment and shall comply with section 606....
-
608.5.1 Transfer Type Shower Compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm) maximum above the shower floor...
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...