, and reflecting pools) and 4.34 Automated Teller Machines (revision of specifications for clear floor space and control heights)....
Search Results "Clear Floor Area"
-
ADAAG
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST Unusual characteristics include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1134A.6 Showers
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
Water Closet Location and Rear Grab Bar
., when a lavatory or other recessed fixture is located next to the water closet and the wall behind the lavatory is recessed so that the lavatory does not overlap the required clear floor...
-
Comparison of Single-User Toilet Room Layouts: Plan 3
An out-swinging door also minimizes the overall layout depth and cannot swing over the required clear floor space or clearance at any accessible plumbing fixture....
-
Transfer Platforms
Clear floor or ground space - used for parking wheelchair or mobility devices (commonly called "wheelchair parking") - is required at the transfer platform. ...
-
Doors [4.35.3]
In rooms with curtained openings, clear floor space requirements for alcoves in 4.2.4 must be provided....
-
Applying the Accessibility Standards to the Plan, Installation, and Maintenance of Ground Level Accessible Routes for Playgrounds
Is there a minimum clear width of 60 inches for the ground level accessible route (some exceptions apply)?...
-
11B-219.4 Location
If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area...
-
11B-219.4 Location
If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot (15240 mm) viewing distance of the stage or playing area...
-
Diagonal Curb Ramps: ADA Standard Section 406.6
Section 406.6 covers the current ADA Standards for diagonal curb ramps.
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1009.2.1 Elevators required
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall...
- Innerface ARQ Interior Sign Frame System
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-406.5.2 Width
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
In alteration projects involving buildings and facilities previously approved and built without elevators, areas above and below the ground floor are subject to the 20-percent disproportionality...
- Rebuilding Together Twin Cities - Minneapolis, MN
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
Change in Direction: ADA Standard Section 405.7.4
Section 405.7.4 covers the current ADA Standards for the change in direction at ramp landings.