The Access Board held a public meeting in July 2010 that featured panel discussions and presentations by experts and researchers on medical equipment accessibility, health care providers...
Search Results "Boarding Area"
-
H. Barriers Affecting Accessibility and Usability of Medical Diagnostic Equipment
-
Examples of making a program accessible are:
It is not necessary to remove physical barriers at the inaccessible campus, if the two campuses offer the same courses, have the same hours, and serve the same geographic area....
-
Vertical Clearance [§307.4]
Barriers at Circulation Areas with Reduced Vertical Clearance Recommendation: A minimum height is not specified for barriers demarcating areas with less than 80” of vertical...
-
When an addition increases the number of stories or square footage beyond the maximum permitted by the exception, is an accessible route between stories required?
Also, if the addition includes a primary function area, an accessible path of travel to the primary function area is required, including where it involves travel between stories or levels...
-
Required Compliance [§209]
Compliance is required only where areas are specifically designed or designated for passenger loading, such as those at airports, many hotels, and convention centers....
-
11B-202.2 Additions
Each addition that affects or could affect the usability of or access to an area containing a primary function shall comply with 202.4. ...
-
Rail Station Signs: ADA Standard Section 810.6
By scanning an area, the person will hear the sign. This means that signs can be placed well out of reach of braille readers, even on parapet walls and on walls beyond barriers....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
11B-1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
11B-209.2.2 Bus loading zones
In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply...
-
11B-209.2.2 Bus loading zones
In bus loading zones restricted to use by designated or specified public transportation vehicles, each bus bay, bus stop, or other area designated for lift or ramp deployment shall comply...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
Rear Wall: ADA Standard Section 604.5.2
Section 604.5.2 covers the current ADA Standards for rear wall grab bars that are used for water closets.
-
11B-1009.3.3 Handrails
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
Handrails: ADA Standard Section 1009.3.3
Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and other pools where user access is limited to one area, the handrails shall not be required to...
-
11B-802.4.2 Identification
If there is no ticket office, the functional equivalent would be in the lobby or at the entrance to the assembly area in a conspicuous location. ◼...
-
11B-802.4.2 Identification
If there is no ticket office, the functional equivalent would be in the lobby or at the entrance to the assembly area in a conspicuous location. ◼...
-
Visual Alarms
Visual Alarms • Where audible fire alarms or emergency notification is provided, flashing lights are required in public and common use areas, including toilet and bath rooms, locker rooms...
-
§ 36.302(f)(3) Identification of accessible seating
companion seats shall be identified on seating maps, plans, brochures, or other information provided to the general public to describe the seating layout or configurations at an assembly area...
-
E2-b
Are pedestrian routes leading to or serving each of the service or activity areas free of overhead objects with the bottom edge lower than 80 inches above the floor?...
-
Sec.36.403(h)(1)
(1) The obligation to provide an accessible path of travel may not be evaded by performing a series of small alterations to the area served by a single path of travel if those alterations...
-
E1-1. Accessible Route
Is there an accessible route, at least 36 inches wide that connects the accessible entrance to the voting area (the accessible route may narrow to 32 inches wide for up to 2 feet in length...
-
6.1(1)
(1) Hospitals - general purpose hospitals, psychiatric facilities, detoxification facilities -- At least 10 percent of patient bedrooms and toilets, and all public use and common use areas...
-
4.16.5* Flush Controls
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....