When an entity determines that a condition in 1019 does not permit full compliance with a specific provision in 1014, Exception 1 permits the camp shelter to comply with the provision to...
Search Results "Comply With"
-
1014.1 General
-
1011.4 Picnic Tables
This section requires picnic tables to comply with the technical requirements for dining surfaces in 902.3 of the Architectural Barriers Act Accessibility Guidelines, which requires the...
-
11B-206.6.1 Existing elevators
of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator and shall comply...
-
11B-224.7 Housing at a place of education
Housing at a place of education subject to this section shall comply with Sections 11B-224.1 through 11B-224.6 and 11B-806 for transient lodging guest rooms....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story residential dwelling units in buildings on a site and shall comply...
-
11B-206.6.1 Existing elevators
of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator and shall comply...
-
11B-224.7 Housing at a place of education
Housing at a place of education subject to this section shall comply with Sections 11B-224.1 through 11B-224.6 and 11B-806 for transient lodging guest rooms....
-
11B-206.4.4.3 Key stations and intercity rail stations
Key stations and existing intercity rail stations required by Subpart C of 49 CFR part 37 to be altered, shall have entrances complying with Section 11B-404....
-
1009.4.2 Area of refuge
The elevator shall be accessed from an area of refuge complying with Section 1009.6. Exceptions: Areas of refuge are not required at the elevator in open parking garages....
-
11B-609.4 Position of grab bars
position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children's use complying...
-
405.9 Edge Protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1....
-
233.3.4.1 Alterations to Vacated Buildings
building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units shall comply...
-
217.2 Wheelchair Accessible Telephones
Where public telephones are provided, wheelchair accessible telephones complying with 704.2 shall be provided in accordance with Table 217.2....
-
609.4 Position of Grab Bars
position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children’s use complying...
-
11B-708.4 Residential dwelling unit communication systems
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with Section 11B-708.4....
-
1007.2, Item 8
Ramps complying with Section 1010, and Chapter 11A, Sections 1114A and 1122A, or Chapter 11B, 11B-405, as applicable....
-
11B-802.2 Lines of sight
Lines of sight to the screen, performance area, or playing field for spectators in wheelchair spaces shall comply with Section 11B-802.2....
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with the following:...
-
11B-1008.3.2.4 Contrasting stripe
Striping complying with Section 11B-504.4.1 shall be provided at each transfer step. FIGURE 11B-1008.3.2 TRANSFER STEPS...
-
F206.4.7 Restricted Entrances
Where restricted entrances are provided to a building or facility, at least one restricted entrance to the building or facility shall comply with 404....
-
F209.4 Valet Parking
Parking facilities that provide valet parking services shall provide at least one passenger loading zone complying with 503....
-
305.4 Knee and Toe Clearance
Unless otherwise specified, clear floor or ground space shall be permitted to include knee and toe clearance complying with 306....
-
606.4 Faucets
Controls for faucets shall comply with 309. Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
810.2.3 Connection
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402....