A171.8FGVR Series is a self-contained, pressure water cooler....
Search Results "Water Closets"
Commonly Searched Documents
- Murdock Manufacturing Barrier-Free 14-Gage Stainless Steel Wall Mount Water Cooler
- Zurn Z5560 Commercial EcoVantage Elongated Toilet ADA Height
-
Element
., telephone, curb ramp, door, drinking fountain, seating, or water closet....
-
ELEMENT
., telephone, curb ramp, door, drinking fountain, seating, water closet....
-
4.34.2(12)
A full bathroom shall include a water closet, a lavatory, and a bathtub or a shower....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
-
11B-805.2.4 Toilet and bathing rooms
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
- Delta Round Front Toilet C41901-WH
-
11B-809.9.7 Exposed pipes and surfaces
Exposed water supply and drain pipes under sinks and lavatories shall comply with Section 11B-606.5....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
4.34.5.2(4)
Figure 47 Water Closets in Adaptable Bathrooms...
-
4.34.5.2(2)
(2) The height of the water closet shall be at least 15 in (380 mm), and no more than 19 in (485 mm), measured to the top of the toilet seat....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
-
11B-213.2.2 Unisex (Patient) toilet rooms in medical care and long-term care facilities
Common-use unisex toilet rooms for exclusive patient use not located within patient bedrooms shall contain a lavatory and one water closet....
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet
-
806 Transient Lodging Guest Rooms
The Department has also modified several accessible guest room plans to show that doors can be installed on closets and comply with the 2010 Standards....
-
11B-603.6 Guest room toilet and bathing rooms
toilet and bathing fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory, urinal, water...
-
11B-604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
F213.3.1 Toilet Compartments
compartment required to comply with 604.8.1, at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water...
-
Compartment Doors
The proposed rule specified the location of doors in the front partition, which were required to be hinged 4 inches from the side wall or partition farthest from the water closet (604.8.1.2...
-
213.3.1 Toilet Compartments
compartment required to comply with 604.8.1, at least one compartment shall comply with 604.8.2 where six or more toilet compartments are provided, or where the combination of urinals and water...
-
4.15.3 Spout Location
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...
-
4.15.3 SPOUT LOCATION
The spouts of drinking fountains and water coolers shall be at the front of the unit and shall direct the water flow in a trajectory that is parallel or nearly parallel to the front of the...