Wheelchair spaces shall not overlap circulation paths. Advisory 11B-802.1.5 Overlap....
Search Results "Space Allowance"
Commonly Searched Documents
-
11B-802.1.5 Overlap
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. [2010 ADAS] Advisory 1004.1 Clear Floor Space. ...
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. [2010 ADAS] Advisory 1004.1 Clear Floor Space....
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
1002.4 Wheelchair Spaces in Amusement Rides
Wheelchair spaces in amusement rides shall comply with 1002.4....
-
1002.4 Wheelchair Spaces in Amusement Rides
Wheelchair spaces in amusement rides shall comply with 1002.4....
-
11B-304.3 Size
Turning space shall comply with Section 11B-304.3.1 or 11B-304.3.2....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-410.3 Clear floor space
Clear floor space in platform lifts shall comply with Section 11B-305....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
11B-403.5.3 Passing spaces
An accessible route with a clear width less than 60 inches (1524 mm) shall provide passing spaces at intervals of 200 feet (60,960 mm) maximum....
-
Clear Floor Space [4.27.2]
Clear Floor Space [4.27.2] Clear floor space for a forward or side approach is required at controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed...
-
4.2.3* Wheelchair Turning Space
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
4.2.3* WHEELCHAIR TURNING SPACE
The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b))....
-
203 General Exceptions
203 General Exceptions Limited Access Spaces and Machinery Spaces....
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
M. Turning Space
M. Is there an area in each public restroom in which a person who uses a wheelchair can turn around - either a 60" diameter circle or a "T"-shaped turn area as shown in Figure 3...
-
Clear Floor Space [4.18.3]
Clear Floor Space [4.18.3] Clear floor space at least 30 inches wide is required, including between partitions where they are provided (when shields do not extend beyond the front of...
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
-
4.3.4 Passing Space
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...
-
4.3.4 PASSING SPACE
If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed...