Toilet stall doors shall comply with 4.13. If toilet stall approach is from the latch side of the stall door, clearance between the door side of the stall and any obstruction may be...
Search Results "Shower Compartment"
-
4.17.5* DOORS
-
604.2 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
604.2 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
ROLL-IN SHOWER STALLS
[See subsections ...]
-
2a
Do large showers measure at least 30" wide by 60" deep as shown in Figure 35(b) below?...
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4....
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4....
-
1a
Do all small showers, if provided in accessible guestroom/suites, measure exactly 36" wide by 36" deep as shown in Figure 35(a) below: [ADA Stds. 4.21.2] Yes __ No __ N/A __ Comments:...
-
4.23 Bathrooms, Bathing Facilities, and Shower Rooms
[See subsections ...]
-
A4.23 Bathrooms, Bathing Facilities, and Shower Rooms
[See subsections ...]
-
A4.23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS
[See subsections ...]
-
4.23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS
[See subsections ...]
-
4.21.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 37.
-
9. Faucet Controls
Do roll-in showers have faucet controls that are easily operable with one hand (i.e.: levers, wrist blades, single arm, etc.) without tight grasping, pinching or twisting of the wrist?...
-
604.2 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
1e
Do all small showers have faucet controls that are easily operable with one hand (i.e.: levers, wrist blades, single arm, etc.) without tight grasping, pinching or twisting of the wrist?...
-
Example of a Single-User Bathroom (with Roll-in Shower)
Example of a Single-User Bathroom (with Roll-in Shower) Clear space required at any fixture can overlap required clear floor spaces, turning space, and door maneuvering space....
-
604.2 Location
side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment...
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
1607A.8.2 Grab bars, shower seats and dressing room bench seats....
-
11B-610 Seats
[See subsections ...]
-
11B-610 Seats
[See subsections ...]
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
1607.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...