The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
Search Results "Patient Lift"
Commonly Searched Documents
-
11B-1009.2.4 Seat
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
The horizontal distance from transfer surface should be no more than 3 inches from the edge of the patient support surface....
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
The transfer surface should be located such that the long dimension of 28 inches is located parallel to the patient scanning/imaging side of the table....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
M301.3.1 Transfer Supports
patient monitoring, etc....
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
M304.1 General
Diagnostic equipment used by patients in a standing position shall comply with M304....
-
Section 37.165 Lift and Securement Use
A lift conforming to Access Board requirements has a platform measuring at least 30” x 48”, with a design load of at least 600 pounds (i.e., capable of lifting a wheelchair/occupant combination...
-
1009.2.6 Footrests and Armrests
EXCEPTION: Footrests shall not be required on pool lifts provided in spas....
-
5.9 Standing Support for Equipment Used by Patients in a Standing Position
5.9 Standing Support for Equipment Used by Patients in a Standing Position....
-
16. I think a lift poses a safety risk at an unattended pool. I also have heard that my insurance rates will increase if I have a lift in my unattended pool. Can I consider safety risks?
I think a lift poses a safety risk at an unattended pool. I also have heard that my insurance rates will increase if I have a lift in my unattended pool....
-
Platform to Runway Clearance: ADA Standard Section 410.4
Section 410.4 covers the current ADA Standards for the required clearance between the platform and any runway landing.
-
Seat Location: ADA Standard Section 1009.2.2
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-410.4 Platform to runway clearance
The clearance between the platform sill and the edge of any runway landing shall be 1¼ inch (32 mm) maximum.
-
§ 38.83(b)(4) Power or equipment failure
Lift platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding any faster than 12 inches/second...
- Harmar CPL800H-1400H Hydraulic CPL with Modular Tower
-
Door Maneuvering Clearance
This exception derives from the original ADAAG and was intended to apply to those types of patient rooms where patients are typically transported in and out by hospital staff....
-
206.7 Platform Lifts, F206.7 Platform Lifts
206.7 Platform Lifts F206.7 Platform Lifts These sections specify where platform lifts are permitted as a component of an accessible route in new construction....
-
F223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
Platform Lifts in Transient Lodging Guest Rooms and Dwelling Units
Platform Lifts in Transient Lodging Guest Rooms and Dwelling Units....
-
M301.3 Transfer Supports
Height: Located no less than 6 inches (150 mm) and no more than 19 inches (482 mm) above the patient support surface Horizontal Distance from Transfer Surface: No more than 3 inches (...