Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
Search Results "Door Height"
Commonly Searched Documents
-
11B-404.2.10 Door and gate surfaces
-
Full-Powered Automatic Doors and Gates [§404.3]
Full-Powered Automatic Doors and Gates [§404.3] Full-powered automatic doors and gates are often found in grocery and retail stores, hotels, and airports to ease passage with shopping...
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum shall be permitted....
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
804.3.2 Height
EXCEPTION: A counter that is adjustable to provide a kitchen work surface at variable heights, 29 inches (735 mm) minimum and 36 inches (915 mm) maximum, shall be permitted....
-
408.3 Elevator Doors
408.3 Elevator Doors. Elevator hoistway doors shall comply with 408.3....
-
2. Door Hardware
Is the bathroom door hardware (levers, pulls, etc.) easily operable with one hand, without tight grasping, pinching or twisting of the wrist, since many persons with disabilities may not...
-
408.3.1 Sliding Doors
408.3.1 Sliding Doors. Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
4.13.11(2)(a)
(a) exterior hinged doors: (Reserved)....
-
408.3.2 Swinging Doors
408.3.2 Swinging Doors. Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
11B-604.9.3 Height
11B-604.9.3 Height. The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....
-
A4.10.7 Door and Signal Timing for Hall Calls
This paragraph allows variation in the location of call buttons, advance time for warning signals, and the door-holding period used to meet the time requirement....
-
A4.10.7 DOOR AND SIGNAL TIMING FOR HALL CALLS
This paragraph allows variation in the location of call buttons, advance time for warning signals, and the door-holding period used to meet the time requirement....
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
-
4.10.7* Door and Signal Timing for Hall Calls
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
4.10.7* DOOR AND SIGNAL TIMING FOR HALL CALLS
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D or T = D...
-
4.35.3 Doors
All doors to accessible dressing rooms shall be in compliance with section 4.13....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with 404....
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]