• An accessible route must provide access to all public and common use areas including the playing field, locker rooms, dugouts, stages, swimming pools, and warm-up areas. The...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
Access to playing fields, lockers, and spaces used by players and performers
-
III-7.3000 Accessible elements and spaces: Scoping and technical requirements
[See subsections ...]
-
11B-213.3.4 Lavatories
213.3.4 implemented by the 2013 CBC Supplement dated July 1, 2015, DSA-AC has increased the number of accessible toilet compartments, ambulatory accessible toilet compartments, accessible urinals...
-
1009.2.1 Elevators required
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall...
- Yale Real Living™ Digital Door Viewer
-
4. Assess During the Planning, Installation and Maintenance Phases
Measure the clear ground space in all directions with a digital level to ensure it is less than 1:48 or 2.08%....
-
11B-205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B-309. Exceptions: 1....
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
Use color and design to create architectural landmarks to aid in spatial orientation (slides 8 – 10)
For example, in the space on the left [in slide 8], there’s a color definition behind the main reception desk. Now, yes, there’s a lot of glare in this space....
-
Change in Direction: ADA Standard Section 405.7.4
Section 405.7.4 covers the current ADA Standards for the change in direction at ramp landings.
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
- Innerface ARQ Interior Sign Frame System
- Federal Elevator Carelift Wheelchair Lift
-
Feature 6 - Restrooms
Feature 6 - Restrooms An accessible restroom with accessible amenities (e.g, drinking fountains) outside the space....
-
Elevator Exemption (Preamble, Section-by-Section Analysis)
For example, a two-story facility built for mixed-use occupancy on both floors (e.g., by sales and rental establishments, a movie theater, restaurants, and general office space) is a shopping...
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
For example, a two-story facility built for mixed-use occupancy on both floors (e.g., by sales and rental establishments, a movie theater, restaurants, and general office space) is a shopping...
-
National Network of ADA Centers
In Section 5.1, pages 66 and 69, justifications for a higher transfer height is made at 25” and chapter 6 (page 139) a more clear discloser is given for a high height number and the exclusion...
-
Height: ADA Standard Section 611.4
Section 611.4 covers the current ADA Standards for the height of the laundry compartment in top loading machines and front loading machines.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....