In the 2010 Standards an exception allows the entry door to swing over the clear floor spaces and clearances required at the fixtures if a clear floor space complying with section 305.3...
Search Results "Space Limitation"
Commonly Searched Documents
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
-
R204.2 Sidewalks
The pedestrian access route shall connect to accessible elements, spaces, and facilities required by this document and to accessible routes required by section 206.2.1 of appendix B to 36...
-
C. Doors
Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within...
-
§382.67(a)
(a) As a carrier, you must ensure that there is priority space (i.e., a closet, or a row of seats where a wheelchair may be strapped using a strap kit that complies with applicable Federal...
-
1003.2.13 Accessible means of egress
Accessible spaces shall be provided with not less than one accessible means of egress....
-
Platform Size and Surface
Platform Size and Surface To be part of an accessible route, lift platforms must provide the amount of clear space required for wheelchairs in ADAAG 4.2.4....
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
§8.3 Accessible route
Accessible route means a continuous unobstructed path connecting accessible elements and spaces in a building or facility that complies with the space and reach requirements of applicable...
-
M14
Is the operating control (switch, lever, button, or pull) for each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor space for a parallel...
-
904.4.2 Forward Approach
Knee and toe space complying with 306 shall be provided under the counter. A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
Accessible Route
A continuous unobstructed path connecting all accessible elements and spaces of a building or facility....
-
4.2.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
4.34.5.5(1) Size and clearances
Shower stall size and clear floor space shall comply with either Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.34.2(15)
(15) The following spaces shall be accessible and shall be on an accessible route: (a) The living area. (b) The dining area....
- ATA - Alliance for Technology Access
- Rebuilding Together Peoria - Peoria, IL
- National Restaurant Association - Americans with Disabilities Act Toolkit
- AbilityApp
-
§382.53(b)
(b) The information you must provide under paragraph (a) of this section includes, but is not limited to, the following: Information concerning flight safety, ticketing, flight check-in,...
-
11B-201.3 Temporary and permanent structures
Temporary buildings or facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed...
-
§ 36.105(d)(2)(ii)
Given their inherent nature, these types of impairments will, as a factual matter, virtually always be found to impose a substantial limitation on a major life activity....
-
4.1.6(1)(k)(ii)
(ii) The exemption provided in paragraph (i) does not obviate or limit in any way the obligation to comply with the other accessibility requirements established in these guidelines....