Eliminating Hazards [4.26.4] Handrails, grab bars, and adjacent surfaces cannot have any sharp or abrasive elements....
Search Results "Curb Ramp Surface"
-
Eliminating Hazards [4.26.4]
-
2.9.1 Natural Elements
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit the allowable extension of natural protruding objects over the ORAR surface...
-
Beach Access Route
A continuous, unobstructed path designed for pedestrian use that crosses the surface of a beach or that leads from a pedestrian access point to the high tide level at tidal beaches; mean...
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. ...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
11B-505.10.2 Top extension at stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. ...
-
11B.707.7.1.3 Horizontally mounted display screen
60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor or ground surface...
-
11B-505.10.2 Top extension at stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
1007.2.1 Buildings with four or more stories
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
-
1003.2.13.1.1 Buildings with four or more stories
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
-
4(2)
., a sunken living room), changes in level greater than 1/2 inch are ramped or have other means of access....
-
What kinds of services must transportation personnel provide?
However, assistance with boarding and disembarking, including pushing a manual wheelchair up a particularly steep ramp, is required....
-
What kinds of services must transportation personnel provide?
However, assistance with boarding and disembarking, including pushing a manual wheelchair up a particularly steep ramp, is required....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, exterior exit stairs and exterior exit ramps. 3. ...
-
III-7.5115 Elevators and platform lifts
above (see III−5.4000). 2) Exception 2 exempts elevator pits, elevator penthouses, mechanical rooms, and piping or equipment catwalks. 3) Exception 3 permits the use of accessible ramps...
-
1009.2.1 Elevators required
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
-
1009.2.1 Elevators required
buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
-
SIDEWALK
[DSA-AC] A surfaced pedestrian way contiguous to a street used by the public. (As differentiated from the definition of “Walk”.) Advisory Definition of SIDEWALK. ...
-
7.4.6 Tread Obstacles
Where the trail surface is paved or is elevated above the natural ground, tread obstacles shall not exceed ½ inch (13 mm) in height measured vertically to the highest point. ...
-
R406.2 Unobstructed Forward Reach
Where a forward reach is unobstructed, the high forward reach shall be 1220 mm (4.0 ft) maximum and the low forward reach shall be 380 mm (1.25 ft) minimum above the finish surface....
-
Check-Out Areas [8.3]
Check-Out Areas [8.3] Check-out counters at accessible lanes are held to a maximum surface height of 36 inches....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter....
-
WALK
[DSA-AC] An exterior prepared surface for pedestrian use, including pedestrian areas such as plazas and courts. (As differentiated from the definition of “Sidewalk”.)...