Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
Search Results "Hybrid Surface System"
-
11B-308.3.1 Unobstructed
-
11B-406.5.12 Detectable warnings
width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back of the curb on the ramp surface...
-
¾ Inch Minus and ¼ Inch Minus Limestone
The surface stayed soft under foot, enough to see footprints compacted and not return to the surface, but did not show any signs of erosion....
-
Alterations to elevators. (Section-by-Section Analysis)
It is therefore possible that a bank of elevators controlled by a single call system may contain just one accessible elevator, leaving an individual with a disability with no way to call...
-
M302.4.1 Clearance in Base
provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
102 Dimensions for Adults and Children
are also provided based on children’s dimensions and anthropometrics for drinking fountains, water closets and other elements located in toilet compartments, lavatories and sinks, dining surfaces...
-
M301.4.1 Clearance in Base
provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
Questionnaire
A full version of the questionnaire given to the subjects after traveling over each surface can be found in Appendix C. The questionnaire was developed by the study investigators....
-
M301.4.1 Clearance in Base
provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
II. Rulemaking History
With respect to announcement systems, these guidelines require large buses operating in fixed route service to be equipped with public address systems that permit announcement of stops or...
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...
-
[2010 ADAS] 105.2.5 NFPA
Exception: Fire alarm systems dedicated to elevator recall control, supervisory service and fire sprinkler monitoring. 23.8.5.4.1 Systems equipped with alarm verification features shall...
-
§ 37.131(a)(2)(i)
(i) For rail systems, the service area shall consist of a circle with a radius of 3/4 of a mile around each station....
-
2. Mirrors
Mirrors: If provided, mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor....
-
e-i
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
5.7.1 Lift Compatibility Clearance in Base for M301
effective, they must deploy at diagnostic equipment such that the boom of the lifts can maneuver far enough over the equipment to safely lower and raise the patient onto and off examination surfaces...
-
11B-705.1.1.3.1
Detectable warning surfaces shall be yellow and approximate 33538 of SAE AMS-STD-595A....
-
§ 37.3 Paratransit
Paratransit means comparable transportation service required by the ADA for individuals with disabilities who are unable to use fixed route transportation systems....
-
Folding Seats on Equipment Used by Patients Seated in a Wheelchair (M302.4 Exception)
However, the folding seat would be required to meet the other technical criteria in M302 for transfer surfaces and supports. Question 28....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
Comments from Individuals Who Are Blind or Have Low Vision (Section-by-Section Analysis)
Analysis) The National Federation of the Blind was a member of the advisory committee that recommended the proposed guidelines, but filed a minority report recommending detectable warning surfaces...
-
Animal Containment Areas
These areas must comply with all ADAAG requirements, except the requirements that surfaces be stable, firm, and slip resistant and the restrictions on changes in level since some surfaces...