For single-user toilet rooms, key considerations include the configuration of water closets and lavatories, clear floor spaces required at fixtures, turning space, the location and swing...
Search Results "Clear Floor Area"
-
Room Dimensions
-
4.1.2(7)
EXCEPTION: In multiple-story buildings and facilities where at-grade egress from each floor is impossible, either of the following is permitted: the provision within each story of approved...
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
- Face® Dipstick® Profiler Precise, Accurate & Repeatable (Concrete/Pavement Flatness & Levelness)
- LaCantina Folding Wood Door System
-
Getting From Here to There—Outdoor Recreation Access Routes
Design outdoor recreation access routes to meet technical requirements for running and cross slopes, resting intervals, surface, clear tread width, passing spaces, tread obstacles, protruding...
-
11B-250.1 General
Physical separation shall be provided with circulation paths raised 4 inches (102 mm) minimum above the area where vehicular traffic occurs....
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: 1. Reserved. 2. Reserved....
-
C. Food Service
.: direct counter service) at counters or bars, is there a minimum 60" long portion providing a 27" high knee space, at least 19" deep, with the counter top at 28"-34" above the floor, or...
-
4(6)
door to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such as concrete, brick or flagstone, are no more than 1/2 inch below the floor...
-
Sales Counters [7.2(1)]
to each "type" it is necessary to consider counters where only certain transactions can be made such as refunds for example, or counters that exclusively serve specific departments or areas...
-
4.1.6(4)(c)
(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2....
- NYC Board of Elections: Video 3 - Accessibility Clerk Responsibilities
-
10. I have already been sued, so I am clear.
False! If you have been sued or paid a settlement and did not fix the issue, then you are still at risk. If you did fix the issue, you may still be responsible for accessibility or...
- ADA Checklist for Existing Facilities
- LaCantina Contemporary Aluminum Bifold Door System
-
Story
That portion of a building or facility designed for human occupancy included between the upper surface of a floor and upper surface of the floor or roof next above....
- SmartCells Flooring: Softer Anti-Fatigue Mats are NOT Better
-
Flush Controls on Toilets
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
10 - foot straightedge method
10 - foot straightedge method This is the classic method for determining the flatness of concrete and other types of finished floors....
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...
-
2. Are play components that have multiple stations or which can include more than one person using them at one time considered one or two play components?
If required to be accessible, a play component must be on an accessible route, have clear floor or ground space and maneuvering space, and have entry points and seats at the required heights...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
