Tactile arrow The tactile arrow on the device must be aligned with the direction of travel on the crosswalk and point toward the street crossing that the pushbutton controls and signals...
Search Results "Visible Signal (Elevator Landing)"
-
Tactile arrow
- Schumacher Elevator Company: Virtual Plant Tour in HD by SAPTV
-
Elevators: ADA Standard Section 216.7
Section 216.7 covers scoping requirements in the current ADA Standards for signs at elevators.
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Private Residence Elevators: ADA Standard Section 409
Section 409 covers the current ADA Standards for private residence elevators.
-
407 Elevators
Section 407 covers passenger elevators, including destination-oriented elevators and existing elevators....
-
Doorways [4.8.4]
Landings must provide the maneuvering clearance at doors required in ADAAG 4.13. ADAAG allows the landing to overlap maneuvering clearances at doors....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3.
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3.
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator...
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
-
A4.10.14 Emergency Communications
A device that requires no handset is easier to use by people who have difficulty reaching. Also, small handles on handset compartment doors are not usable by people who have...
-
A4.10.14 EMERGENCY COMMUNICATIONS
A device that required no handset is easier to use by people who have difficulty reaching.
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall be provided in accordance with Sections 907.5.2.3.1 through 907.5.2.3.4. Exceptions: 1....
-
4.10.9 Floor Plan of Elevator Cars
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car....
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car....
-
R407.6.1 Slope
Landing slopes shall be 2 percent maximum in any direction....
-
Keypads: ADA Standard Section 407.4.6.3
Section 407.4.6.3 covers the current ADA Standards for elevator car control keypads.