Floor or ground surfaces shall comply with Section 11B-302....
Search Results "Surface Slope"
Commonly Searched Documents
-
11B-403.2 Floor or ground surface
-
11B-403.2 Floor or ground surface
Floor or ground surfaces shall comply with Section 11B-302....
-
11B-403.2 Floor or ground surface
Floor or ground surfaces shall comply with Section 11B-302....
-
Measuring Surface Firmness and Stability
The rotational penetrometer (RP) is a precision surface-indenter measuring tool for evaluating the firmness and stability of ground and floor surfaces (figure 1). ...
-
11B-804.3.3 Exposed surfaces
There shall be no sharp or abrasive surfaces under the work surface counters....
-
11B-804.3.3 Exposed surfaces
There shall be no sharp or abrasive surfaces under the work surface counters....
-
11B-804.3.3 Exposed surfaces
There shall be no sharp or abrasive surfaces under the work surface counters....
-
404.2.10 Door and Gate Surfaces
404.2.10 Door and Gate Surfaces....
-
4.1.6(4)(a)
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit the use of a 1...
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed....
-
302.1 Floor or Ground Surfaces
302.1 Floor or Ground Surfaces Both section 4.5.1 of the 1991 Standards and section 302.2 of the 2010 Standards require that floor or ground surfaces along accessible routes and in accessible...
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
4.1.6 Surface
The surface of the clear floor or ground space shall be firm and stable. The type of surface should be appropriate to the setting and level of development. ...
-
4.6.6 Surface
The surface of the clear floor or ground space required by section 4.6.4 shall be firm and stable. The type of surface should be appropriate to the setting and level of development. ...
-
404.2.10 Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
4.1.6(3)(a) Ramps
(a) Ramps: Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may...
-
R407.7 Surfaces
R407.7 Surfaces. Surfaces of ramp runs and landings shall comply with R302.7....
-
1002.4.1 Floor or Ground Surface
1002.4.1 Floor or Ground Surface. The floor or ground surface of wheelchair spaces shall be stable and firm....
-
A4.8.1 General
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
A4.8.1 GENERAL
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
Smooth Surface
Section 404.2.10 requires that swinging doors and gates have a smooth surface on the push side that extends their full width....
-
5.1.7 Surface
The surface of the clear ground space shall be firm and stable....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3, 11B-409.4.3, 11B-410.4, 11B-810.5.3...
-
4.3.4 Tent Pad or Platform Surface