The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005....
Search Results "Stroke Width"
Commonly Searched Documents
-
1132A.3, Item 6
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
Additional Features of Van-Accessible Parking Spaces
parking spaces incorporate the features of accessible parking spaces on the previous page and require the following additional features: a "van accessible" designation on the sign; different widths...
-
§ 38.95(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...
-
Shower and Sauna Doors in Transient Lodging Facilities
Standards and section 206.5.3 of the 2010 Standards both require passage doors in transient lodging guest rooms that do not provide mobility features to provide at least 32 inches of clear width...
-
§ 38.107(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1220 mm) between handrails....
-
1007.7.6 Stairway
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
H17
H17. Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No
-
9. Exterior Ramps
9. ...do the exterior ramps have the following features: a. top and bottom landings that are level, at least as wide as the ramp they serve, and at least 60" long to allow for...
-
B2
B2. Does each accessible parking space have its own, or share, an adjacent access aisle that is least 60 inches (5 feet) wide? [ADA Standards § 4.6.3] Yes No
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
A2. Access Aisle
A2. Does each accessible parking space have its own, or share an adjacent access aisle that is least 60 inches (5 feet) wide? [ADA Stds 4.6.3] Yes _____ No _____
-
A7. Curb Ramps
A7. If there is a curb between the access aisle and the accessible route to the building, is there a curb ramp that meets the following requirements: [ADA Stds 4.7] a. Is the ramp...
-
8.4 Card Catalogs and Magazine Displays
Minimum clear aisle space at card catalogs and magazine displays shall comply with Fig. 55. Maximum reach height shall comply with 4.2, with a height of 48 in (1220 mm) preferred...
-
8.4 CARD CATALOGS
Minimum clear aisle space at card catalogs, magazine displays, or reference stacks shall comply with Fig. 55. Maximum reach height shall comply with 4.2, with a height of 48 in (1370...
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
§ 38.95(a)(1) General
(1) General. All new commuter rail cars, other than level entry cars, covered by this subpart shall provide a level-change mechanism or boarding device (e.g., lift, ramp or bridge...
-
§ 38.83(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop....
-
9.2* POST OFFICE LOBBIES
Clear passageways in front of customer service counters shall be not less than 48 in (1220 mm) clear width to permit maneuvering of a wheelchair....