Steel – polished and plated or phosphated and prime coated for painting or Stainless Steel – highly polished or satin finish. For corridor doors to patients’ rooms, operating...
Search Results "Stroke Width"
Commonly Searched Documents
- Stanley FBB 269 Heavy Weight Ball Bearing “Swing Clear” Offset Door Hinge
-
11B-502.7 Relationship to accessible routes
Parking spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes....
-
Using the ORAR Exceptions [F202.3, Exception 4 and 1016, Exceptions 1, 2, and 3]
For instance, where traffic calming devices, gates, or other barriers are provided on a paved roadway, the ORAR must have a clear width of 36 inches and obstacles cannot exceed one-half...
-
11B-406.5.3 Landings
The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing....
-
11B-406.5.3 Landings
The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing....
-
Accessible Routes Throughout the Museum
and a stanchion, passage must be maintained at a minimum of 36 inches wide, measured from inside edge to inside edge of the stanchion bases or floor moldings, except at doors where the width...
-
1017.4 Passing Spaces
Trails with a clear tread width less than 60 inches (1525 mm) shall provide passing spaces complying with 1017.4 at intervals of 1000 feet (300 m) maximum. ...
-
1017.4 Passing Spaces
Trails with a clear tread width less than 60 inches (1525 mm) shall provide passing spaces complying with 1017.4 at intervals of 1000 feet (300 m) maximum....
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
4.4.1* General
Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e))....
-
9.5.2(2)(a)
(a) at least one public entrance shall allow a person with mobility impairments to approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
4.4.1* GENERAL
Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e)). Figure 8 Protruding Objects...
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
(1)(e)
(e) Doorways on the end of the enclosure, opposite the water closet, should have a minimum clear opening width of 32 inches (815 mm)....
-
§ 38.23(c)(2) Ramp surface
The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch high; shall have a clear width of 30 inches; and shall accommodate...
-
§ 38.83(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater then 1/4 inch, shall have a clear width of 30 inches, and shall...
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
-
Elevated Accessible Routes
A typical elevated accessible route might include the following: 36-inch (915 mm) clear width 32-inch (815 mm) narrowed width permitted for 24-inch (610 mm) length to accommodate...
-
Measuring Door Openings
This measures the clear width of the door opening through which people pass, which is less than the width of the door itself....
-
1017.2 Aisles in assembly spaces
1017.2 Aisles in assembly spaces. Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1028.
-
N. Health Units/Medical Care Areas
N. Health Units/Medical Care Areas In many schools, where emergency shelters are often located, nurses' rooms or other types of health care facilities may be provided. These...
-
G. Compartment Size
G. If the accessible toilet is in a stall, does the stall measure at least 60" wide and 56" deep if it is wall mounted or 59" deep if it is floor mounted to allow persons who use...
-
N1
N1. Is there an accessible route, at least 36 inches wide, that connects each of the shelter activity areas with the health units and medical care areas (it may narrow to 32 inches...
-
K2
K2. Is there an accessible route that is at least 36 inches wide that connects accessible tables with serving, condiment, and dispenser areas? [ADA Standards § 5.3;...