In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
Search Results "Sleeping Compartment"
Commonly Searched Documents
-
223.1 General
- Jacknob Corp. 7033 Surface Mounted Self-Closing Hinge Set
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level are not...
-
4.17.3 SIZE AND ARRANGEMENT
The size and arrangement of toilet stalls shall comply with Fig. 30(a). Toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a)) shall have wall-mounted water closets....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
A4.17.3 Size and Arrangement
This section requires use of the 60 in (1525 mm) standard stall (Figure 30(a)) and permits the 36 in (915 mm) or 48 in (1220 mm) wide alternate stall (Figure 30(b)) only in...
- Scranton Toilet Partitions: Eclipse - Floor Mount Headrail
- Figure 604.2 Water Closet Location – Drawing from the U.S. Access Board
- General Partitions ADA Door Pull Kit (6300HC)
- Willoughby Industries ADA Cabinet Shower US-FA-HC
- Hager Companies Round Wrought Door Pull 4
- Jacknob Corp. 6251 3" High ADA Door Pull Brass-Chrome
- General Partitions ADA Door Pull Kit (6300HC-SS)
- Hager Companies Rectangular Wrought Door Pull 2
- Hager Companies Round Wrought Door Pull 3
- Hager Companies Security Pull T4E
- Hager Companies Security Pull P4E
- SafePath SafeShower™ Ramp Transitions
- Willoughby Industries US-HC Cabinet Shower
- Boost Your Business - Chapter 10 - Restroom Fixtures
-
Toilet Rooms-Special Exhibit Space
Toilet Rooms-Special Exhibit Space: u. The force required to push or pull open the restrooms' vestibule doors is 10 lbf, which exceeds the maximum allowable door opening force of...
-
H27
H27. Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor? [ADA Standards §...
-
C. Accessibility Within Toilet Rooms
C. Accessibility Within Toilet Rooms C1-a. Is there an area within the toilet room where a person who uses a wheelchair or mobility device can turn around - either a minimum...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...