The audio output shall provide verbal instruction for the user to press the accessibility function button as a response to verbal direction in order to select the destination floor....
Search Results "Push Button"
Commonly Searched Documents
-
11B-411.2.1.7.2 Assignment by touch screen hall call console
-
11B-404.2.4.1 Swinging doors and gates
to doorway (beyond latch side unless noted) From front Pull 60 inches (1524 mm) 18 inches (457 mm)5 From front Push...
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable....
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
Automatic Doors and Power Assisted Doors [4.13.12]
Most operate slowly, allow manual opening, and are often activated by a push button or plate....
-
Size: ADA Standard Section 407.4.6.2.1
Section 407.4.6.2.1 covers the current ADA Standards for the size of the elevator car control buttons.
-
Size: ADA Standard Section 409.4.6.1
Section 409.4.6.1 covers the current ADA Standards for the size of the car controls in private residence elevators.
-
Car Controls: ADA Standard Section 409.4.6
Section 409.4.6 covers the current ADA Standards for the car controls in private residence elevators.
- Don-Jo Mfg., Inc. Push Plate 69
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush....
-
Emergency Communication
The ASME A17.1 code (section 2.27) requires provision of a push button labeled "HELP" which, when activated, initiates a call for help and establishes two-way communication....
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3....
- AJW Architectural Products U127 40 oz. Vertical Liquid Soap Dispenser w/ Push-up Valve - Surface Mounted
-
Visible Indicators: ADA Standard Section 407.4.7.1.4
Section 407.4.7.1.4 covers the current ADA Standards for visible indicators on elevator car control buttons.
-
11B-407.4.7.1.4 Visible indicators
Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
-
A4.13.11 Door Opening Force
Although most people with disabilities can exert at least 5 lbf (22.2N), both pushing and pulling from a stationary position, a few people with severe disabilities cannot exert 3 lbf (13.13N...
-
A4.13.11 DOOR OPENING FORCE
Although most people with disabilities can exert at least 5 lbf (22.2N), both pushing and pulling from a stationary position, a few people with severe disabilities cannot exert even 3 lbf...
-
ASME: ADA Standard Section 105.2.2
Section 105.2.2 of the ADA Standards cover references to the American Society of Mechanical Engineers (ASME) standards.
-
Door and Signal Timing: ADA Standard Section 407.3.4
Section 407.3.4 covers the current ADA Standards for door and signal timing of elevator reopening devices.
-
11B-407.3.4 Door and signal timing
T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) directly in front of the farthest call button...