Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location...
Search Results "Primary Accessible Means of Entry"
-
1009.8.2 Directions
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and a central control point location approved by the fire department. Where the central...
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location and a central control point...
-
1009.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location...
-
§ 35.151(b)(4)(iii)(A)
(A) Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds twenty percent (20%) of the...
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
-
SECTION 1013 EXIT SIGNS
[See subsections ...]
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
entry of the multi-story residential dwelling unit shall be on an accessible route....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
entry of the multi-story residential dwelling unit shall be on an accessible route....
-
E202.6.3 Alternative Means
one or more requirements in the Revised 508 Standards imposes an undue burden or a fundamental alteration in the nature of the ICT, the agency shall provide individuals with disabilities access...
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
6d.
Does the lift allow a wheelchair user unassisted entry, operation, and exit? Yes _____ No _____...
-
General [§202.1]
Additional requirements apply to projects that affect or could affect the usability of, or access to, an area containing a primary function....
-
1009.3.3 Handrails
At least two handrails complying with 505 shall be provided on the sloped entry....
-
Accessible Routes: ADA Standard Section 1003.2
Accessible routes serving recreational boating facilities, including gangways and floating piers, shall comply with Chapter 4 except as modified by the exceptions in 1003.2....
-
1010.1.4 Floor elevation
At exterior doors serving Groups F, H, R-2 and S and where such doors are not part of an adaptable or accessible route or, not required to be accessible by Chapter 11A or 11B of the California...
-
1010.1.4 Floor elevation
At exterior doors serving Groups F, H, R-2 and S and where such doors are not part of an adaptable or accessible route or, not required to be accessible by Chapter 11A or 11B of the California...
-
1. Technical Standard for Web Site Accessibility
standard for all public-facing Web pages involved in marketing air transportation to the general public in the United States on primary carrier and ticket agent Web sites....
-
f-iv
Does the lift allow a person using a mobility device unassisted entry, operation (is key available, if required), and exit? Yes No...
-
1009.3.3 Handrails
At least two handrails complying with 505 shall be provided on the sloped entry....
-
Web Site Accessibility
We proposed to limit the scope of the carriers' responsibility to ensure agent Web site accessibility to the Web sites of agents that are not small businesses as defined by the Small Business...
- EZ-ACCESS Suitcase Singlefold Ramp