Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
Search Results "Primary Accessible Means of Entry"
-
4.13.2 Revolving Doors and Turnstiles
-
4.13.2 REVOLVING DOORS AND TURNSTILES
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
1007.7 Exterior area for assisted rescue
Exterior areas for assisted rescue shall be accessed by an accessible route from the area served....
-
F202.4 Alterations Affecting Primary Function Areas
Camping facilities, picnic facilities, viewing areas, trailheads, trails, and beach access routes shall not be required to comply with F202.4....
-
11B-809.8.2 Door opening force
Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3....
-
§ 36.403(a)(1)
(1) An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure that, to the maximum extent...
-
1009.4.1 Standby power
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety...
- S.R. Smith PAL2 202-0000 Pool Lift
-
1002.1 Definitions
The following terms are defined in Chapter 2: ACCESSIBLE MEANS OF EGRESS. AREA OF REFUGE. EXIT. GUARD ([DSA-AC, HCD 1 & HCD 2] or GUARDRAIL). HANDRAIL....
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
1002.1 Definitions
The following terms are defined in Chapter 2: ACCESSIBLE MEANS OF EGRESS. AREA OF REFUGE. EXIT. GUARD ([DSA-AC, HCD 1, HCD 2 & HCD 1-AC] or GUARDRAIL). HANDRAIL....
-
Alterations and Additions [§206.2.3.1, §202.4]
An accessible route to stories or mezzanines may be required as part of an accessible path of travel to primary function areas that are altered or added (§202.4)....
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
Alterations [4.1.6(1)(f) & (k)]
In alterations, ADAAG does not require a level of access greater than that required in new construction....
-
Gangway Alterations
However, if the areas altered contain primary functions (such as a fishing station), existing gangways are considered part of the path of travel to the altered primary function areas and...
-
Submerged Depth
Submerged Depth Sloped entries must extend to a depth between 24 inches minimum and 30 inches maximum below the stationary water level....
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
206 Accessible Routes
1991 Standards for Accessible Design 2010 Standards for Accessible Design What’s New/Different 206.2.8 Employee...
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....