Areas of refuge are not required for stairways accessed from a refuge area in conjunction with a horizontal exit....
Search Results "Horizontal Projection"
-
1009.3.3 Area of Refuge
-
1009.4.2 Area of refuge
Areas of refuge are not required for elevators accessed from a refuge area in conjunction with a horizontal exit....
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
1009.2.1 Elevators required
automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required as part of the accessible means of egress on floors provided with a horizontal...
-
Character Height: ADA Standard Section 703.5.5
Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further approach towards the sign....
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
5b. Ramp Slope
[ADA Stds 4.7.2] Note: 1:12 is one inch of vertical height for 12 inches of horizontal distance. Yes _____ No _____...
-
609.8 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting device...
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
-
1132A.9 Smooth surface
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other and be free of sharp or abrasive edges....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor (shown the vertical axis) and (b) offset distance (shown on the horizontal...
-
Grab bar clearance
Have local authorities accepted one-piece dispensers in toilet compartments that are recessed behind the horizontal grab bars? These units stick out ¼" or so....
-
R408.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
- SCI Empowerment Project by University of Washington Department of Rehabilitation Medicine
-
Public Building
(v) On or used in connection with river, harbor, flood control, reclamation or power projects, or for chemical manufacturing or development projects, or for nuclear production, research,...
-
Knee and Toe Clearance (M303.2.4)
The Wheeled Mobility Anthropometry Project showed that these dimensions do not accommodate many people in the sample and recommended alternative dimensions that would accommodate 95 percent...
-
Issue 22: How is accessibility for persons with low vision assessed during the design review process?
[If] that person doesn’t give [the regional officer] the project to review, or [doesn’t] tell [the regional officers] this project needs review, then [the regional officer doesn’t] review...
-
TRANSIT BOARDING PLATFORM
[DSA-AC] A horizontal, generally level surface, whether raised above, recessed below or level with a transit rail, from which persons embark/disembark a fixed rail vehicle....
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....