Are the faucet controls and shower wand positioned on the wall along the side of the shower seat so they are operable from the folding shower seat or from the shower wheelchair?...
Search Results "Emergency Control"
Commonly Searched Documents
- 
    
  
  4. Faucet Controls
  
- 
    
  
  J. Drinking Fountains
  The spout and controls of the drinking fountain must be near the front edge. The controls must be usable with one hand without tight grasping, pinching, or twisting of the wrist.... 
- 
    
  
  11B-411.2.1.4.2 Security or access controls
  Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility.... 
- 
    
  
  11B-411.2.1.4.2 Security or access controls
  Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility.... 
- 
    
  
  11B-411.2.1.4.2 Security or access controls
  Security or access control system card readers associated with elevator operation shall be in close proximity to each hall call console in a consistent manner throughout the facility.... 
- 
    
  
  4.3.8 Operating forces 
  Designers should reduce the need for high precision grip postures and/or pinch forces given the lack of finger dexterity, motor control or pinching capabilities of persons with disabilities... 
- 
    
  
  402.2.1 User Control
  Speech output for any single function shall be automatically interrupted when a transaction is selected. Speech output shall be capable of being repeated and paused. 
- 
    
  
  106.5 Defined Terms, F106.5 Defined Terms
  * * * * * Emergency Transportable Housing Unit.... 
- 
    
  
  703.7.2.3 Volume Control Telephones
  Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 703.7.2.3.... 
- 
    
  
  Safety Considerations for Site Selection
  Choose facilities that are protected by audible and visible fire alarms and a fire sprinkler system. The U.S. Fire Administration has a list of approved hotels and motels. It is... 
- 
    
  
  B. Conducting Accessibility Surveys
  Conducting Accessibility Surveys The following Quick-Check Survey (beginning on page 7) and the ADA Checklist for Emergency Shelters (beginning on page 11) are designed to assist State... 
- 
    
  
  Temporary Solutions For Emergency Sheltering - Protruding Object Hazards
  Temporary Solutions For Emergency Sheltering - Protruding Object Hazards Problem: Objects protrude too far from the side into the route causing a hazard for people who are blind or who... 
- 
    
  
  L. Availability of Electrical Power
  Availability of Electrical Power Emergency shelters should have a way to provide a back-up power supply when the electrical service is interrupted.... 
- 
    
  
  § 38.83(b)(2) Controls
  (2) Controls—... 
- 
    
  
  Controls [9.2.2(5)]
  Controls [9.2.2(5)] All controls in accessible units, sleeping rooms, and suites must comply with 4.27, which provides specifications for clear floor space, height of operable controls... 
- 
    
  
  Fact Sheet on Obtaining and Using Employee Medical Information as Part of Emergency Evacuation Procedures
  [See subsections ...] 
- 
    
  
  809.2.5 Bedrooms in Emergency Transportable Housing Units
  of a bed in bedrooms in emergency transportable housing units.... 
- 
    
  
  Check-in:
  1. * If you know you will have difficulty, because of walking, mobility, seeing or hearing or other issues, in case of emergency, (i.e., fire, evacuation, etc.) consider: 1.1 Let the... 
- Stryker Stair-PRO 6252
- 
    
  
  11B-409.4.6 Car controls
  Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.... 
- 
    
  
  703.7.2.3 Volume Control Telephones
  Telephones with a volume control shall be identified by a pictogram of a telephone handset with radiating sound waves on a square field such as shown in Figure 703.7.2.3.... 
- 
    
  
  11B-409.4.6 Car controls
  Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.... 
- 
    
  
  11B-409.4.6 Car controls
  Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.... 
- 
    
  
  A4.10.12 CAR CONTROLS
  Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments.... 
